3
-
31
(4) Mounting TE Bracket 2
1
.
Check the names of the cables that are to be housed in Renewal Kit ①. Check the abbreviations and short
names of the connectors to the servo amplifier. Connect the cables and the connectors. (Signal names are
different. See Fig. 1 to check the signal names before connecting the cables.)
2.Use the screws provided as accessories in the package (M4×8; 4 screws) to mount the TE bracket 2
③ on the amplifier base ② (with the replacing servo amplifier mounted).
③TE bracket 2
①Cables housed in Renewal Kit
②Amplifier base (with the replacing
servo amplifier mounted)
Note 1
Short-circuit bar (on the replacing servo amplifier)
Do not remove the short-circuit bars if you do not use the
power-factor improvement DC reactor.
P
1
(P
3
)
(P
4
)
P(P+)
C
N(N-)
P
3
P
4
P+
C
N-
Fig. 1
Conversion terminal
block on Renewal Kit
J4 terminal
block
(Note 1)
TE2
bracket
Destination of Connection
Steps in paragraph (4) and the following
step are performed after the servo
amplifier is mounted on the control
panel. In this manual, the servo
amplifier is seen from a different angle
for you to easily understand what to do.
* When you are going to use the power-factor improvement DC reactor, go on to paragraph (6).
When you are not going to use the power-factor improvement DC reactor, go on to paragraph (5).