2-37
2.5.6 SC-J2SBJ4KT5K
(1) Primary replacement (when replacing the servo amplifier only)
(for SC-J2SBJ4KT5K)
Encoder
Servo motor
for MR-J2S
Make sure to remove the power supply between P and D.
Control signal
conversion cable
1-phase
100 V AC
(
Note3)
CN10A
CN10B
CN3
CN2
24 V DC
power supply
connection
cable
200 V AC to
230 V AC
3-phase
Renewal kit
(SC-J2SBJ4KT
K)
Servo amplifier
(MR-J4-
B-RJ020)
Encoder
conversion
cable
SSCNET conversion unit
(MR-J4-T20)
Power supply for I/F
(24 V DC)
Control signal
Controller
or
Servo amplifier
Servo amplifier
or
Terminal resistor
Analog monitor
Connection of regenerative option
Regenerative
option
(
Note1)
Note1)
(
Note2)
(
Note 1. When using the regenerative option, make sure to remove the wiring between P+ and D, connect with the wiring between the
renewal kit and the servo amplifier, and mount the regenerative option between P+ and C. Ensure the connection destinations
are correct. The servo amplifier may malfunction if the connection destinations are incorrect.
For details, refer to MR-J4-_B-RJ020 Series Servo Amplifier Technical Reference Material issued by Mitsubishi Electric
Corporation.
2. There is no conversion terminal block in the SC-J2SBJ4KT5K renewal kit. Directly connect to the MR-J4 servo amplifier.
For details, refer to MR-J4-_B-RJ020 Series Servo Amplifier Technical Reference Material issued by Mitsubishi Electric
Corporation.
3. Required only when the internal power supply (24 V DC) for the I/F is used in the existing MR-J2S-_B_ servo amplifier. Not
included with the renewal tool. Note that a separate 24 V DC power supply (current capacity: 80mA and over) is required when
replacing.
When connecting the 24 V DC power supply, use the "24 V DC power supply connection cable (model: SC-J2SJ4CTPWC5M)"
included in the package.
(Electric wire colors: Red (+ side); white (- side))
No.
Product name
(1)
Servo amplifier
*1
(2)
Servo motor
*1
(3)
SSCNETconversion unit
*1
(4)
Renewal kit
(5)
Encoder conversion cable
(6)
Control signal conversion cable
(7)
24 V DC power supply
connection cable
*1: Manufactured by Mitsubishi Electric.
2 - 37