A-3
4. Additional instructions
The following instructions should also be fully noted. Incorrect handling may cause a malfunction, injury,
electric shock, etc.
(1) Transportation and installation
CAUTION
●
Transport the products correctly according to their mass.
●
Stacking in excess of the specified number of product packages is not allowed.
●
Do not hold the front cover when transporting the servo amplifier. Otherwise, it may drop.
●
Install the servo amplifier and the servo motor in a load-bearing place in accordance with the Instruction
Manual.
●
Do not get on or put heavy load on the equipment.
●
The equipment must be installed in the specified direction.
●
Secure the prescribed distance between the servo amplifier and the inner surface of the cabinet or other devices.
●
Do not install or operate the servo amplifier and servo motor which have been damaged or have any parts
missing.
●
Do not block the intake and exhaust areas of the servo amplifier. Otherwise, it may cause a malfunction.
●
Do not drop or strike the servo amplifier and servo motor. Isolate them from all impact loads.
●
When you keep or use the equipment, please fulfill the following environment.
Item
Environment
Operation
0
C to 55
C (non-freezing)
Ambient
temperature
Storage -20
C to 65
C (non-freezing)
Operation
Ambient
humidity
Storage
90 %RH or less (non-condensing)
Ambience
Indoors (no direct sunlight) and free from corrosive gas, flammable gas, oil mist, dust, and dirt
Altitude
1000 m or less above sea level
Vibration resistance
5.9 m/s
2
, 10 to 55 Hz (Each direction of X, Y, and Z)
●
Contact your local sales office if the product has been stored for an extended period of time.
●
When handling the servo amplifier, be careful about the edged parts such as corners of the servo amplifier.
●
The servo amplifier must be installed in a metal cabinet.
●
Take sterilization and insecticide measures other than fumigation for the wood packing material. If a servo
amplifier is packed with wood packing material that has been smoked or fumigated, halogenated material
contained in the fumigant (such as fluorine, chlorine, bromine, and iodine) may cause the servo amplifier to
malfunction.
●
Therefore, because a malfunction may occur, avoid using the servo amplifier in an environment where the
servo amplifier coexists with parts containing halogenated flame retardants (such as bromine).
A - 3