Section 6 - Storage
Page 126
90-864839061 NOVEMBER 2006
BOAT OUT OF THE WATER
NOTE: Use this procedure if the air actuated single point drain system fails.
NOTE: It may be necessary to lift, bend, or lower hoses to allow water to completely drain
when hoses are disconnected.
1. Place the boat on a lever surface to ensure complete draining of the system.
2. Remove two blue drain plugs from the seawater pickup pump (front, starboard side).
a
17255
a
a -
Blue drain plug locations
3. Verify that water is draining from each opening.
4. Allow the system to drain for a minimum of five minutes. Mercury MerCruiser
recommends leaving the drain system open while transporting the boat or while
performing other maintenance to ensure that all water is drained.
5. For DTS engines, pull the lanyard stop switch (if equipped), or disable the ignition circuit
by pulling the fuse marked "CD".
6. Crank the engine over slightly with starter motor to purge any water trapped in the
seawater pickup pump. Do not allow the engine to start.
7. Prior to launching the boat or starting the engine, close the drain system by installing
the two blue drain plugs.
Draining the Sterndrive
NOTE: This procedure is needed only for salty, brackish, mineral laden, or polluted water
applications; and for freezing temperatures or extended storage.
Summary of Contents for 496 MAG Bravo
Page 26: ...Section 1 Warranty Notes Page 18 90 864839061 NOVEMBER 2006 ...
Page 50: ...Section 2 Getting to Know Your Power Package Notes Page 42 90 864839061 NOVEMBER 2006 ...
Page 72: ...Section 4 Specifications Notes Page 64 90 864839061 NOVEMBER 2006 ...
Page 74: ...Section 5 Maintenance Page 66 90 864839061 NOVEMBER 2006 ...
Page 142: ...Section 7 Troubleshooting Notes Page 134 90 864839061 NOVEMBER 2006 ...