INSTALLATION INSTRUCTIONS
TT-1501
9/12a
Original Issue Date:
9/09
Model:
40--180EOZD/EOZC and 33--150EFOZD/EFOZC
Market:
Marine
Subject:
Full Feature Panel Kits
Introduction
Installation of the Full Feature Panel kit allows generator
set starting/stopping from a location remote from the
generator set. The panel includes an illuminated DC
voltmeter,
engine
oil
pressure
gauge,
coolant
temperature gauge, and hourmeter. See Figure 1 for kit
selection. Use these kits on generator sets equipped
with Decision-Maker
r
3+ controllers. See Figure 2 for
panel features.
Note:
The installation of the Full Feature Panel requires
the control wiring kit GM51368-KP1 (33--99 kW)
or
GM51368-KP2
(100--180
kW)
unless
customer provided. See Figure 18.
Generator Set
Kit No.
Model
Voltage
40EOZD/EOZC,
33EFOZD/EFOZC
12
GM51369-KP1
24
GM51369-KP2
55/65EOZD/EOZC,
40/50EFOZD/EFOZC
12
GM51369-KP3
24
GM51369-KP4
80/99EOZD/EOZC,
70/80EFOZD/EFOZC
12
GM51369-KP5
24
GM51369-KP6
125EOZD/EOZC,
100EFOZD/EFOZC
12
GM51369-KP7
24
GM51369-KP8
150EOZD/EOZC,
125EFOZD/EFOZC
12
GM51369-KP9
24
GM51369-KP10
180EOZD/EOZC,
150EFOZD/EFOZC
12
GM51369-KP11
24
GM51369-KP12
Figure 1
Kit Selection
The DC voltmeter
measures the voltage of the starting
battery(ies).
Check
the
battery
manufacturer’s
recommendation for correct operating voltage.
The engine oil pressure gauge
measures the engine
oil pressure.
Refer to the following instructions for
locating the oil pressure sender.
Note:
During the engine break-in period, the engine
sometimes produces high oil pressure readings.
Consult the service manual for specific values.
A-344404-T
1. Frequency meter
2. Voltmeter
3. Ammeter
4. Ammeter switch
5. On light
6. Start/stop switch
7. Hourmeter
8. Volt gauge
9. Temperature gauge
10. Oil pressure gauge
6
7
8
9
10
1
2
3
4
5
Figure 2
Panel Features
The coolant temperature gauge
measures the engine
coolant temperature. Refer to the following instructions
for locating the coolant temperature sender.
The hourmeter
records the total generator set
operating
hours
for
reference
in
maintenance
scheduling.
Note:
For generator sets already in service, the
hourmeter
on
the
controller
will
have
accumulated hours and, therefore, reflect a
different reading than the panel hourmeter. Use
the same hourmeter each time to schedule
maintenance.