Sheeter SVC 525C
79
Operating and display elements, operating modes
Temperature indicator, heating of cutting unit
1
<Actual temperature of heating, drive side> display
2
<Actual temperature for production release, drive side> display
3
<Actual temperature for production release, operator side> display
4
<Actual temperature of heating, operator side> display
Illustration 41: Temperature indicator, heating of cutting unit
4
3
1
2
He
at
in
g d
is
p
la
y
,
oper
a
to
r side (
4
)
Produc
tion r
e
leas
e disp
la
y
,
oper
a
to
r side (
3
)
He
at
in
g d
is
p
la
y
,
drive s
ide
(1)
Produc
tion r
e
leas
e disp
la
y
,
drive s
ide
(2)
Min. temperature threshold, heating
38 °C
-
38 °C
-
Max. temperature threshold, heating
41 °C
-
41 °C
-
Display area during production
1)
38 °C -
44 °C
38 °C -
44 °C
38 °C -
44 °C
38 °C -
44 °C
Temperature threshold for production
release
-
33 °C
-
33 °C
Min. alarm threshold
10 °C
10 °C
10 °C
10 °C
Max. alarm threshold
60 °C
60 °C
60 °C
60 °C
Sensor interruption
u u u
u u u
u u u
u u u
Sensor short circuit
o o o
o o o
o o o
o o o
Table 23: Temperature display
1) A fluctuation of the temperature display during production is normal and is caused by the set hysteresis charac-
teristic curve.
Summary of Contents for SVC 525C
Page 1: ...Sheeter Translation of the original operating manual Keep for future reference SVC525C ...
Page 48: ...44 Sheeter SVC 525C Product description Technical data ...
Page 66: ...62 Sheeter SVC 525C Structure and function Protective devices ...
Page 90: ...86 Sheeter SVC 525C Transport interim storage Interim storage of the machine ...