Sheeter SVC 525C
41
Product description
Technical data
3.2.4
Electrical supply
Electrical supply
1)
Wiring diagram no. See electrical name plate
Nominal voltage
3 x 400 V + N + PE
2)
Required mains configu-
ration
3)
TN - C - S -
power mains
TN - S - power
Clockwise rotat-
ing field required
Voltage
400 V AC
+/-10%
Frequency
50 Hz
+/-1 %
Control voltage:
24 VDC/10 A
Connecting line
4)
Cross-section (IEC)
mm
2
Cross-section (UL)
Max. line length
m
Min. network impedance
mOhm
Short-circuit current rating
(SCCR) according to UL
508A
6 kA
Fuse
IEC
63 A characteristic C
UL
63 A
Protective equipotential
bonding conductor
5)
Cross-section according
to IEC
10 mm
2
Connected loads
Total
6)
Approx. 14 kW
Operational readiness
(stand-by)
Power
kW
Current rate
A
Table 15: Electrical supply 400V network
1) Stationary mains connection
2) If the existing nominal voltage varies from the supply voltage specified above, an isolating transformer must be in-
stalled.
If the nominal voltage is 380 V or 415 V at 50 Hz, the tolerance of the power mains must be checked.
If the tolerance is between 360 V – 440 V, an isolating transformer is not required.
3) N - line is loaded; a fault-current circuit breaker (FI) may not be used.
4) According to EN ISO 60204:2006 Table 10.
5) According to EN 60204:2006.
6) The total connected load depends on the number and equipment of the connected machines.
Summary of Contents for SVC 525C
Page 1: ...Sheeter Translation of the original operating manual Keep for future reference SVC525C ...
Page 48: ...44 Sheeter SVC 525C Product description Technical data ...
Page 66: ...62 Sheeter SVC 525C Structure and function Protective devices ...
Page 90: ...86 Sheeter SVC 525C Transport interim storage Interim storage of the machine ...