background image

Lingenfelter NCC-001

Nitrous Control Center

Installation and Operating

Instructions

Lingenfelter Performance Engineering

1557 Winchester Road

Decatur, IN 46733

(260) 724-2552

(260) 724-8761 fax

www.lingenfelter.com

Release Date: October 26, 2012

PN: L460150000

Revision 1.2

Summary of Contents for NCC-001

Page 1: ...rol Center Installation and Operating Instructions Lingenfelter Performance Engineering 1557 Winchester Road Decatur IN 46733 260 724 2552 260 724 8761 fax www lingenfelter com Release Date October 26...

Page 2: ...Launch Controller 29 NCC 001 Connected to the LNC 2000 for Simple On Off Control 29 NCC 001 Connected to the Pin on the ECM for EFILive Nitrous Operating System and Fuel Control 31 Connecting the NCC...

Page 3: ...Percent Per Pulse 82 13 Resume Fuel Percentage Part VII Setup Menu 85 85 1 Erase Data Log 86 2 Analog Out Menu 87 Graph Type 87 Analog Out Graph Setup 89 3 Timer Setup Menu 95 4 Shift Setup Menu 95 5...

Page 4: ...rol Center Installation and Operating Instructions 3 161 1 Appendix A Pulse Frequency Detailed Explanation 162 2 Appendix B Nitrous and Fuel Operation 163 3 Appendix C Tables and Diagrams 166 4 Append...

Page 5: ...Introduction Part I...

Page 6: ...the NCC 001 software program are also available on the controller itself The NCC 001 controller also features enough internal memory to save three user defined nitrous programs for quick access in th...

Page 7: ...hicle speed possible other inputs later o Software enable disable pull up resistor on frequency input Engine speed tach input o Software enable disable pull up resistor on tachometer input o Accepts m...

Page 8: ...LPE recommends that nitrous safety solenoids be used anytime the primary nitrous solenoids are pulse width modulated The use of nitrous safety solenoids allow the flow of nitrous to be terminated in t...

Page 9: ...3 Limited Warranty LPE warrants the Lingenfelter NCC 001 Nitrous Control Center to be free from defects in material and workmanship under normal use and if properly installed for a period of 180 days...

Page 10: ...nal labels as well as ring terminals with heat shrink insulation on one end The wiring descriptions and diagrams in this manual that involve connecting the NCC 001 to a fuel or nitrous pressure sensor...

Page 11: ...Parts List Part II...

Page 12: ...ing terminal 16 22 AWG DK321288 1 LPE 9 decal L920010000 2 LPE bumper stick sponsor decal 10 3 4 x 3 1 4 L920180000 1 Binder 1 Instructions 2 1 Additional Required Components Description Item ID PN Ni...

Page 13: ...C 001 harness 10 ft L480310000 LNC 2000 Launch Control Module with timing retard feature L460145297 Red LED 7 warning light 10 ft two wire cable RP WLRBLK001 Red LED lighted paddle toggle switch 20 am...

Page 14: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 13 Nitrous sensor harness PN L480300000 NCC 001 harness PN L480310000...

Page 15: ...Installation of the NCC 001 Nitrous Control Center Part III...

Page 16: ...power wires and the solenoid ground wires should all be 16 gauge wire All other wires can be 20 gauge wire Refer to Appendix C Tables and Diagrams for a chart showing the recommended gauge for a leng...

Page 17: ...Installation of the NCC 001 Nitrous Control Center 16...

Page 18: ...OUND2 to the Ground1 and Ground2 terminals on the NCC 001 and to the battery ground stud Be sure to connect BOTH ground wires Since the NCC 001 controls the ground side of the solenoids much more curr...

Page 19: ...Installation of the NCC 001 Nitrous Control Center 18...

Page 20: ...s to control the solenoids see example wiring instructions in section 3 1 3 Connect the striped dark brown wire labeled N2O SLND 1 to the N2O Solenoid1 terminal on the NCC 001 and to Nitrous Solenoid...

Page 21: ...Installation of the NCC 001 Nitrous Control Center 20...

Page 22: ...h of the nitrous stages If using relays to control the solenoids see example wiring instructions in section 3 1 3 Connect the striped dark brown wire labeled N2O SLND 1 to the N2O Solenoid1 terminal o...

Page 23: ...Installation of the NCC 001 Nitrous Control Center 22...

Page 24: ...utomotive relays solid state relays and mechanical automotive relays should not both be used to control solenoids in the same circuit The solenoids being activated through the mechanical automotive re...

Page 25: ...1 Next a wire should connect pin 86 to a fused 12 volt source such as the battery Finally use a wire to connect pin 30 on the relay to a reliable ground source Connect the striped green wire labeled N...

Page 26: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 25...

Page 27: ...sk should be connected to a blow down tube that allows nitrous to be vented out of the vehicle in the event that the safety disk ruptures Before using the nitrous bottle s make sure that they are prop...

Page 28: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 27...

Page 29: ...terminal on the NCC 001 controller is capable of connecting to 2 separate wires at a time If there are more than two wires going to a single terminal as may be the case with the sensor ground termina...

Page 30: ...the production ECM to control the additional fuel needed for nitrous and to modify the ignition timing based on nitrous activation The 12 volt output from Relay 2 is connected to the ECM and the Relay...

Page 31: ...he wire slides into a locking tang inside the connector NOTE You should here a click when the wire terminal engages the locking tang If no audible click is heard the locking tang is not fully engaged...

Page 32: ...voltage signal on the throttle One reason for using the TPS signal instead of the APP signal is that the throttle can be at a different angle than what the APP is requesting As an example during a fu...

Page 33: ...This is the wire that communicates the throttle position to the PCM Splice a wire onto the TPS signal wire Use the labeled wire from the NCC 001 wiring harness or crimp a terminal to the other end of...

Page 34: ...ss Locate the TPS signal wire 1 This is one of the two wires that relay the throttle position signal to the ECM Splice a wire onto the TPS signal wire Use the labeled wire from the NCC 001 wiring harn...

Page 35: ...diagrams below may differ from the wiring in your vehicle Identify the wires of the clutch position sensor harness in your vehicle and confirm their individual functions before beginning one of the mo...

Page 36: ...n switched voltage The use of a relay as shown in the wiring diagram below is necessary due to the fact that the clutch pedal position switch is only powered during vehicle start up When connecting to...

Page 37: ...Installation of the NCC 001 Nitrous Control Center 36...

Page 38: ...12 volt signal that the Clutch Input on the NCC 001 is looking for This conversion can be accomplished through the use of a Clutch TPS switch signal conversion module The Clutch TPS switch signal con...

Page 39: ...Installation of the NCC 001 Nitrous Control Center 38...

Page 40: ...the controller The controller can be connected via USB cable to any computer equipped with Windows XP Windows Vista or Windows 7 The current installed software version or build number can be viewed t...

Page 41: ...ble After extracting the NCC 001 software from the LPE supplied media or downloading the software from the LPE website save the compressed ZIP file to your computer the file was saved to the desktop i...

Page 42: ...ter Installation and Operating Instructions 41 The welcome screen for the Nitrous Control Center Setup Wizard should appear at this time Click the Next button to continue on to installation Click the...

Page 43: ...s well as how much dick space will be left on each disk drive if the Nitrous Control Center software is installed LPE recommends clicking the Disk Cost button to verify that there is enough disk space...

Page 44: ...ion and Operating Instructions 43 The installation confirmation dialog box will appear next Click Next to begin installation of the NCC 001 software The back button is available if it is necessary to...

Page 45: ...The Installation Complete dialog box should appear after a short period of time Click the Close button to exit the installation wizard An icon named Nitrous Control Center should now appear on the de...

Page 46: ...ftware locate the directory folder where your user program files and data logs are saved to verify that they are not located in the Nitrous Control Center program file folder on your C drive When upda...

Page 47: ...d because the NCC 001 controller can only interact with the computer interface if the controller s major software build number matches that of the NCC 001 PC program After extracting the NCC Firmware...

Page 48: ...wse button to select a different location for the software if desired Click the Disk Cost button to display the available disk space on each of the computer s available disk drives The final option in...

Page 49: ...ter 48 The installation confirmation dialog box will appear next Click Next to begin installation of the NCC Controller FLASH Utility software The back button is available if it is necessary to go bac...

Page 50: ...nstructions 49 The Installation Complete dialog box should appear after a short period of time Click the Close button to exit the installation wizard An icon named NCC Controller FLASH Utility should...

Page 51: ...to the computer via USB cable the information inside the Nitrous Control Center USB Connection Status dialog box should be filled out as shown below If the controller is powered OFF and or the control...

Page 52: ...ck on the Update NCC in the menu bar and click on Update NCC Flash Image with Backup Before the firmware installation can begin the Update Software option found in the Global Menu must be selected on...

Page 53: ...he flash data from the controller and saving a backup in case the flash that will be sent to the controller in the next step is corrupt Once the computer has read the flashed data from the NCC 001 con...

Page 54: ...ller The dialog box below shows that installation of the new firmware is complete as well as the location of the backed up firmware on the computer Click OK to continue The final dialog box lets the u...

Page 55: ...Getting to Know the User Interface Part IV...

Page 56: ...the buttons and display on the NCC 001 as well as NCC computer interface The display may slightly change depending on what options have been enabled on the controller For example the Analog 1 input t...

Page 57: ...Getting to Know the User Interface 56 4 2 The Main And Settings Screen Main Screen on the NCC 001 Setting Screens on the NCC 001...

Page 58: ...Lingenfelter NCC 001 Nitrous Control Center Installation and Operating Instructions 57 4 3 The Computer Interface Status Screen...

Page 59: ...Global Menu Setup Options Part V...

Page 60: ...a later time Example you have a setup that is working well but you would like to try a few different settings You could then select and copy all current setup data to a new setup and make changes wit...

Page 61: ...SETUP button The copy current program option is found in the Program dialog box under the Options Tab Select the desired setup to copy the current program to from the pull down menu and click the COPY...

Page 62: ...Tab Click ON to enable the Hold Wait feature or OFF to disable the feature 5 4 Main Timer This setting controls the main timeout period in seconds This controls the total time elapsed before a system...

Page 63: ...rcent to be 25 less than the Nitrous percentage A fuel trim setting of 0 does not allow the fuel to be less than the nitrous in the stage1 or stage2 graphs Valid Range is 0 to 100 in 0 1 increments Ac...

Page 64: ...til the Set Input Polarity menu selection is highlighted and then press the ENTER button Using the LEFT and RIGHT arrow buttons adjust the setting Press the SAVE button to accept the new setting or pr...

Page 65: ...is normally used when connecting to the engine speed signal output from an ECM that is not connected to any other systems or modules in the vehicle On vehicles that already have this signal connected...

Page 66: ...rom a Message Box the default selection will be chosen after 20 seconds NOTE When the Automatic Help feature is ON there is an option on the help prompt screen that allows the user to disable the feat...

Page 67: ...d then press the ENTER button Press the YES NO or CANCEL button to change the current selection If the NO or CANCEL button is pressed no change will be made 5 12 Display Contrast Use this Setting to a...

Page 68: ...utton press the DOWN arrow button repeatedly until the About menu selection is highlighted and then press the ENTER button Press the BACK button to exit Access from the Computer Program From the Statu...

Page 69: ...Nitrous Menus Nitrous1 N2O 1 and Nitrous2 N2O 2 Part VI...

Page 70: ...stage begins after being activated The delay applies to the entire stage which includes nitrous and fuel A Fuel Advance can also be used so that the fuel may be started before the nitrous if desired...

Page 71: ...ow button repeatedly until the Nitrous Quick Setup menu selection is highlighted and then press the ENTER button Using the UP and DOWN arrow buttons select the setting to be changed and hit ENTER Adju...

Page 72: ...t the stage by pressing either the Nitrous1 button or the Nitrous2 button The Nitrous Start Percent setting is found in the Nitrous Quick Setup dialog box under the Nitrous Graph Tab Click the UP and...

Page 73: ...0 to 9 900 seconds in 100 second increments Access from the Controller From the Main screen select the stage by pressing either the N2O 1 button or the N2O 2 button Press the DOWN arrow button to high...

Page 74: ...ENTER button to accept the new setting Use the LEFT and RIGHT arrow buttons to move to the next set point Each cursor position represents One pulse of the Nitrous Solenoid Press the EDIT button and a...

Page 75: ...LEFT RIGHT keys move the Highlight between data points Use the scroll wheel and the right button on the mouse to zoom in or out Single click off from a data point and drag the mouse to move around a z...

Page 76: ...the fuel trim option is changed from the default value of 0 Press the ENTER button to accept the new setting Use the LEFT and RIGHT arrow buttons to move to the next set point Each cursor position rep...

Page 77: ...to zoom in or out Single click off from a data point and drag the mouse to move around a zoomed in window Hit ESC to deselect the edit point You can also single click directly on highlighted Edit poi...

Page 78: ...the Status screen select the stage by pressing either the Nitrous1 button or the Nitrous2 button The Nitrous On RPM setting is found in the Nitrous Control RPM dialog box under the Options Tab Click t...

Page 79: ...us For the maximum OFF RPM setting this is the percentage below the set RPM point that re enables the nitrous Refer to Appendix D Glossary of Terms for an explanation of how a hysteresis works Access...

Page 80: ...ted and then press the ENTER button Using the LEFT and RIGHT arrow buttons adjust the setting Press the SAVE button to accept the new setting or press the ESC button to exit with no change Access from...

Page 81: ...nd that the solenoids pulse A lower setting generally will provide a more linear power delivery as well as allow for lower starting percentages to be used A higher pulse frequency results in more sole...

Page 82: ...Ramp If the Resume Start Percent is greater than the current Nitrous percent the Resume Ramp is ignored Valid Range is 10 to 100 in 1 increments A setting of 100 disables this feature no ramp instant...

Page 83: ...r the Nitrous2 button The Resume Per Pulse setting is found in the Nitrous Resume Ramp dialog box under the Options Tab Click the UP and DOWN arrow buttons or type in any numeric value in the valid ra...

Page 84: ...reen select the stage by pressing either the Nitrous1 button or the Nitrous2 button The Resume Per Pulse setting is found in the Nitrous Resume Ramp dialog box under the Options Tab Click the UP and D...

Page 85: ...Setup Menu Part VII...

Page 86: ...options in the Setup Menu such as the Analog Output feature allow the NCC 001 to control other devices 7 1 Erase Data Log This setting allows the user to manually erase the last data log from the NCC...

Page 87: ...an ECM for external fuel or spark control as well as to link to other devices such as the LPE LNC 2000 Launch Controller LPE PN L460145297 to create a progessive timing retard effect Currently the an...

Page 88: ...ess the ENTER button two 2 times Use the UP and DOWN arrow buttons to adjust the setting Press the ENTER button to accept the new setting or press the BACK button to exit with no change Access from th...

Page 89: ...y edit points that are set in the Graph Screen This does NOT change any Percentage setting only the cursor is removed View Old Data This selection will display the Progressive Ramp that is stored in m...

Page 90: ...NCC 001 based on time or engine RPM The following options are available in the TIMER SETUP menu If the Timer Output Option is set to a time based output the Timer Delay and Timer Duration settings wil...

Page 91: ...Output menu selection is highlighted and then press the ENTER button Press the ENTER button to select the Time Based option and press ether the YES or NO button to change the current selection If the...

Page 92: ...e Options Tab Click ON to enable the Timer Hold feature or OFF to disable the Timer Hold feature Timer Delay This setting controls the amount of Delay before the 12V Timer Output turns on after the ni...

Page 93: ...nd increments Access from the Controller From the Main screen press the SETUP button and then press the ENTER button Press the DOWN button continuously until the Timer Setup Menu is selected then pres...

Page 94: ...change Access from the Computer Program From the Status screen press the Timer button The Output RPM On option is found in the RPM Based Setup dialog box under the Options Tab Click the UP and DOWN a...

Page 95: ...RPM the Timer Output is turned on Then when engine speed exceeds 8000 RPM the Timer Output is turned off As the engine RPM drops the Timer Output is turned on when the engine speed drops below 8000 R...

Page 96: ...nd RIGHT arrow buttons adjust the setting Press the SAVE button to accept the new setting or press the ESC button to exit with no change Access from the Computer Program From the Status screen press t...

Page 97: ...ressed no change will be made Access from the Computer Program From the Status screen press the SETUP button The TPS Activation Enable option is found under the TPS Input Tab Click ON to enable the TP...

Page 98: ...0 in 0 1 increments of full scale 100 Access from the Controller From the Main screen press the SETUP button Press the DOWN arrow button repeatedly until the TPS Setup Menu selection is highlighted a...

Page 99: ...selection is highlighted and then press the ENTER button Press the down arrow until the Set TPS Voltage selection is highlighted and then press the ENTER button For a vehicle equipped with an electro...

Page 100: ...any numeric value in the valid ranges shown above Manually Set Maximum Wide Open Throttle TPS Voltage This setting allows the user to manually select the voltage with the Throttle Position Sensor in t...

Page 101: ...rom the Controller From the Main screen press the SETUP button Press the DOWN arrow button repeatedly until the Analog1 Setup Menu selection is highlighted and then press the ENTER button Once in the...

Page 102: ...etting is found in the Analog Clutch Setup dialog box under the Analog1 Tab Click the UP and DOWN arrow buttons or type in any numeric value in the valid ranges shown above Analog1 Clutch Activation H...

Page 103: ...ehicle The valid range is 0 00 5 00 in 0 01 Volt increments Access from the Controller From the Main screen press the SETUP button Press the DOWN button repeatedly until the Analog1 Setup Menu selecti...

Page 104: ...er Program From the Status screen press the SETUP button The Clutch Pedal Released Voltage setting is found in the Analog Clutch Setup dialog box under the Analog1 Tab Click the UP and DOWN arrow butt...

Page 105: ...his option allows you to put a user controlled switch in the vehicle to manually erase the data log Access from the Controller From the Main screen press the SETUP button Press the DOWN arrow button r...

Page 106: ...ected Access from the Controller From the Main screen press the SETUP button Press the DOWN arrow button repeatedly until the AFR Setup Menu selection is highlighted and then press the ENTER button Pr...

Page 107: ...e the AFR Disable setting before disabling the nitrous system This allows the system to filter out short Lean spikes The Valid Range is 0 000 to 1 000 Seconds in 01 second increments Access from the C...

Page 108: ...1 increments Access from the Controller From the Main screen press the SETUP button Press the DOWN arrow button repeatedly until the AFR Setup Menu selection is highlighted and then press the ENTER bu...

Page 109: ...e AFR Input Setup dialog box under the Air Fuel Ratio Tab Click the UP and DOWN arrow buttons or type in any numeric value in the valid ranges shown above AFR Maximum Voltage This setting should be se...

Page 110: ...the Controller From the Main screen press the SETUP button Press the DOWN arrow button repeatedly until the AFR Setup Menu selection is highlighted and then press the ENTER button Press the down arro...

Page 111: ...type in any numeric value in the valid ranges shown above 7 9 Relay1 and Relay2 Setup Menus The Relay1 output is a NCC 001 controlled ground output The Relay2 output is a NCC 001 controlled 12 volt o...

Page 112: ...t are enabled Access from the Controller From the Main screen press the SETUP button Press the DOWN arrow button repeatedly until the desired Relay Menu is highlighted and then press the ENTER button...

Page 113: ...tle Position Sensor TPS Percentage Control Option If this option is enabled the selected Relay output is controlled by TPS input and any other control options that are enabled Access from the Controll...

Page 114: ...ogram From the Status screen select the relay by pressing either the Relay1 button or the Relay2 button The AFR Enable option is located in the Relay Control Options dialog box Check the box to enable...

Page 115: ...button to change the current selection If the NO button is pressed no change will be made Access from the Computer Program From the Status screen select the relay by pressing either the Relay1 button...

Page 116: ...cycle and any other control options that are enabled Access from the Controller From the Main screen press the SETUP button Press the DOWN arrow button repeatedly until the desired Relay Menu is highl...

Page 117: ...he Status screen select the relay by pressing either the Relay1 button or the Relay2 button The RPM Enable option is located in the Relay Control Options dialog box Check the box to enable the RPM Con...

Page 118: ...select the Fuel PSI Control option then the YES or NO button to change the current selection If the NO button is pressed no change will be made Access from the Computer Program From the Status screen...

Page 119: ...ss the ENTER button This menu is not currently functional so press OK to exit 7 11 Hall Input Menu The following options are found in the Hall Input Menu which can be accessed by the SETUP button on t...

Page 120: ...ble the option If the Hall Input is turned ON in the computer software program the user will also have the ability to enable either stage of nitrous via the vehicle MPH In order for the controller to...

Page 121: ...ess the SETUP button Press the DOWN arrow button repeatedly until the Hall Input Menu selection is highlighted and then press the ENTER button twice Press the DOWN arrow button until the either the Ni...

Page 122: ...omputer Program From the Status screen press either the Nitrous1 or Nitrous2 buttons The Nitrous OFF MPH setting is found in the Nitrous Control MPH dialog box under the Options Tab Click the UP and D...

Page 123: ...e Per Mile setting for the vehicle using live data from the vehicle The valid range is 1000 20000 in 1 Pulse Per Mile PPM increments Access from the Controller From the Main screen press the SETUP but...

Page 124: ...r the Hall Input Tab Click the UP and DOWN arrow buttons or type in any numeric value in the valid ranges shown above Hall Pull Up Option This option enables or disables a 4 7k Ohm pull up resistor to...

Page 125: ...ired fuel pressure Default Sensor Setup Option Use this to configure the controller to select the sensor calibration curve There are two 2 standard sensors available from LPE both of which are pre loa...

Page 126: ...dly until the Fuel PSI Menu selection is highlighted and then press the ENTER button Press the down arrow until the Fuel PSI Min Volt selection is highlighted and then press the ENTER button Use the L...

Page 127: ...or Setup dialog box under the Fuel Sensor Tab Click the UP and DOWN arrow buttons or type in any numeric value in the valid ranges shown above Fuel Pressure Minimum Value This setting should be the fu...

Page 128: ...he Main screen press the SETUP button Press the DOWN arrow button repeatedly until the Fuel PSI Menu selection is highlighted and then press the ENTER button Press the down arrow until the Fuel PSI Ma...

Page 129: ...type in any numeric value to change the settings Fuel PSI Nitrous Oxide Disable This setting determines the fuel pressure at which the nitrous system is disabled A setting of 0 0 will disable this fe...

Page 130: ...se the LEFT and RIGHT arrow buttons adjust the setting Press the SAVE button to accept the new setting or press the ESC button to exit with no change Access from the Computer Program From the Status s...

Page 131: ...nu The following options are found in the Nitrous PSI Menu which can be accessed by the SETUP button on the main screen or by clicking the Nitrous Sensor tab in the Setup menu of the computer software...

Page 132: ...ller From the Main screen press the SETUP button press the DOWN arrow button repeatedly until the Fuel Psi Menu selection is highlighted and then press the ENTER button Press the down arrow until the...

Page 133: ...ighlighted and then press the ENTER button Use the LEFT and RIGHT arrow buttons adjust the setting Press the SAVE button to accept the new setting or press the ESC button to exit with no change Access...

Page 134: ...arrow buttons or type in any numeric value in the valid ranges shown above Nitrous Pressure Maximum Value This setting should be the nitrous pressure that corresponds to the Nitrous sensor maximum vo...

Page 135: ...itch and clutch pedal are engaged In other words data logging is disabled while the clutch pedal is depressed When the clutch pedal is released the data logging feature is enabled In order to prevent...

Page 136: ...button until the TPS Enable option is highlighted then press ENTER Press the YES or NO button to change the current selection If the NO button is pressed no change will be made Once the TPS Enable op...

Page 137: ...the BACK button to exit or the ENTER button to adjust the RPM Enable Percent and Hysteresis Percent settings Refer to Appendix D Glossary of Terms for an explanation of how a hysteresis works Access...

Page 138: ...og Menu where you can either press the BACK button to exit or the ENTER button to adjust the MPH Enable Percent and Hysteresis Percent settings Refer to Appendix D Glossary of Terms for an explanation...

Page 139: ...User Program Files Data Logs and Other Software Options Part VIII...

Page 140: ...ed into memory on the NCC 001 Controller as well as those on the computer Program Start User Program This option allows the user to choose whether the default user program file or the last user progra...

Page 141: ...n the Open User Program File window the computer program should display the following window for the user to browse the computer to find the desired user program file NCD Once the user has selected th...

Page 142: ...ashed from the controller Access from the Computer Program There are three 3 ways to save a User Program File denoted below by the bullet points Press Ctrl S From the Status screen click on the File b...

Page 143: ...ed program click Save to save the current user program file or click Cancel to terminate the operation New User Program File This option allows the user to create a new user program file that can be c...

Page 144: ...3 programs at a time All other user programs must be backed up by using the Nitrous Control Center software If the controller already has three existing user programs and the user attempts to flash a...

Page 145: ...upload of the user program is complete it becomes your current user program on the computer software NOTE Since the uploaded user program becomes the current program you will be prompted to save any...

Page 146: ...er Program to Controller button From the Status screen click on the Save User Program to Controller button in the toolbar on the upper left hand side of the window as shown below Once the Save User Pr...

Page 147: ...ullet points From the Status screen press the DATA button The Read Data from Controller option is found in the NCC Data Log Commands dialog box under the Options tab From the Status screen click on th...

Page 148: ...he Status screen press the DATA button The Open option is found in the Data Log File dialog box under the Options tab From the Status screen click on the Open Data Log from File button in the toolbar...

Page 149: ...Program Files Data Logs and Other Software Options 148 After the data log is opened the file name will be displayed in the Data Log File dialog box The data log can now be viewed under the Data View...

Page 150: ...Erase Data Log from Controller This option allows the user to erase a data log off of the NCC 001 controller Access from the Computer Program From the Status screen click on the Eraser Icon in the to...

Page 151: ...the computer If the controller settings are changed after the data log took place but before the data log was read to the computer the data log user program settings will reflect the controller settin...

Page 152: ...wing Data Logs The following sub sections explain how to view data logs in the Nitrous Control Center computer program The data log chart feature allows the user to view readings of the following vari...

Page 153: ...urement at a single point on the chart To view a reading at any point in the chart simply click and drag the vertical blue bar to any point in time on the chart The chart will then display the reading...

Page 154: ...tangle will span the entire length of the graph as well This can be seen in the previous illustration as that chart was zoomed out completely Notice in the following illustration how the green rectang...

Page 155: ...rolling the Chart Along the X Axis The data log chart can be scrolled along the X axis when the chart is zoomed in by clicking and dragging the white bar that moves along the tick marks on the X axis...

Page 156: ...ables can be displayed at one time by specifying the desired variables in the data view properties dialog box Access from the Computer Program While viewing the data log in the Data View tab of the co...

Page 157: ...Chart The default data log chart is a series of individual charts showing each variable that is checked in the chart properties dialog box but you can also choose to show all of the checked variables...

Page 158: ...peat one of the steps denoted by the bullet points above Loading Data View Properties This option allows the user to open a saved data view properties file Access from the Computer Program From the St...

Page 159: ...ogram From the Status screen press the DATA button The Save Properties option is found in the Data View Properties dialog box under the Options tab A windows explorer window will pop up and prompt the...

Page 160: ...h modifies the chart the least to aggressive which modifies the chart the most The graphs can be smoothed further by repeatedly clicking on these buttons Note that smoothing the data will make the dat...

Page 161: ...Appendices Part IX...

Page 162: ...rous and Fuel Progressive Ramps should be checked The reason for this is the way the NCC 001 stores the data For example a setting of 12 5 Hertz generates fewer data points over a given time interval...

Page 163: ...efore the first nitrous solenoid pulse It is recommended to check nozzle flow and total volume flow to insure correct fuel delivery Nitrous Fuel Progressive Ramp Once armed and the delay and fuel adva...

Page 164: ...es 4 pulse 360 degrees 4 Typical 8 cylinder engines 5 pulse 360 degrees 5 Typical 10 cylinder engines 6 pulse 360 degrees 6 Typical 12 cylinder engines TABLE 2 Common Vehicle ECM PCM Tachometer Signal...

Page 165: ...lack 57 N A N A Corvette 1996 C2 Black 8 Dark Green White 817 Corvette 1997 1998 C1 Red 55 Dark Green White 817 Corvette 1999 2003 C2 Red 50 Dark Green White 817 Corvette 2004 C2 Green 50 Dark Green W...

Page 166: ...0 20 20 2 24 20 20 20 20 20 20 20 20 3 36 20 20 20 20 20 20 20 20 4 48 20 20 20 20 20 20 20 18 5 60 20 20 20 20 20 20 18 18 6 72 20 20 20 20 20 18 18 16 7 84 20 20 20 20 18 18 16 16 8 96 20 20 20 18 1...

Page 167: ...abled in order to prevent the component from switching on and off rapidly If a thermostat for example was to maintain a temperature of exactly 72 degrees it would most likely overshoot 72 degrees and...

Page 168: ...composed of roughly 64 nitrogen and 36 oxygen Because nitrous oxide has a higher concentration of oxygen than air more fuel can be injected into the combustion chambers creating more power output fro...

Page 169: ...m Value 124 Fuel Pressure Maximum Voltage 124 Fuel Pressure Menu 124 Fuel Pressure Minimum Value 124 Fuel Pressure Minimum Voltage 124 Fuel Pressure Option 124 Fuel Psi Menu 124 Fuel Trim Option 62 Fu...

Page 170: ...on 110 RPM Hysteresis Percentage 78 S Save User Program File 139 Set Clutch Voltage 100 Set Input Polarity 63 Set TPS Voltage 95 Shift Input Control Option 110 Shift Setup Menu 95 T Tachometer Pull Up...

Page 171: ...erformance Engineering 1557 Winchester Road Decatur IN 46733 260 724 2552 260 724 8761 fax www lingenfelter com L460150000 NCC 001 Nitrous Control Center v1 2 mnl Photo by SDW Photography The LPE Cama...

Reviews: