1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver
and any required firmware updates.
2. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured via
F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed
Selection, or the ASU Utility.
3. If problem persists, then remove Adapter Card. If system reboots successfully without the
adapter, replace that card.
4. (Trained Service technician only) Replace the system board.
5. (Trained Service technician only) Replace the processor.
•
S.3020007 [S.3020007]
Explanation:
A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault
Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies
to this error.
2. Update the UEFI image.
3. (Trained service technician only) Replace the system board.
•
S.3028002 [S.3028002]
Explanation:
Boot permission timeout detected. Boot Permission Negotiation Timeout
Severity
Error
User Response
Complete the following steps:
1. Check CMM/IMM logs for communication errors and resolve.
2. Reseat the system
3. If problem persists contact support
•
S.3030007 [S.3030007]
Explanation:
A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault
Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to
this error.
2. Update the UEFI image.
3. Replace the system board.
•
S.3040007 [S.3040007]
Appendix B. UEFI/POST diagnostic codes
701
Summary of Contents for NeXtScale n1200
Page 115: ...Chapter 6 Removing and replacing server components 101 ...
Page 117: ...Chapter 6 Removing and replacing server components 103 ...
Page 119: ...Chapter 6 Removing and replacing server components 105 ...
Page 135: ...Chapter 6 Removing and replacing server components 121 ...
Page 137: ...Chapter 6 Removing and replacing server components 123 ...
Page 139: ...Chapter 6 Removing and replacing server components 125 ...
Page 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Page 877: ......
Page 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...