User Response
1. Check the system-event log.
2. (Trained technician only) Remove the failing microprocessor from the system board (see
Removing a microprocessor and heat sink).
3. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
4. Make sure that the two microprocessors are matching.
5. (Trained technician only) Replace the system board.
•
806f0813-2582ffff : An Uncorrectable Error has occurred on [SensorElementName]. (PCIs)
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132582ffff or 0x806f08132582ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0240
User Response
1. Check the system-event log.
2. (Trained technician only) Remove the failing microprocessor from the system board (see
Removing a microprocessor and heat sink).
3. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
4. Make sure that the two microprocessors are matching.
5. (Trained technician only) Replace the system board.
•
806f0813-2584ffff : An Uncorrectable Error has occurred on [SensorElementName]. (CPUs)
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132584ffff or 0x806f08132584ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
Appendix A. Integrated Management Module 2.1 (IMM2.1) error messages
483
Summary of Contents for NeXtScale n1200
Page 115: ...Chapter 6 Removing and replacing server components 101 ...
Page 117: ...Chapter 6 Removing and replacing server components 103 ...
Page 119: ...Chapter 6 Removing and replacing server components 105 ...
Page 135: ...Chapter 6 Removing and replacing server components 121 ...
Page 137: ...Chapter 6 Removing and replacing server components 123 ...
Page 139: ...Chapter 6 Removing and replacing server components 125 ...
Page 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Page 877: ......
Page 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...