User Response
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions for that error event and restart the server.
3. Check the Lenovo support website for an applicable retain tip or firmware update that applies to
this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED
is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
•
806f040c-2004ffff : [PhysicalMemoryElementName] Disabled on Subsystem
[MemoryElementName]. (DIMM 4)
This message is for the use case when an implementation has detected that Memory has been Disabled.
May also be shown as 806f040c2004ffff or 0x806f040c2004ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix:
PLAT
ID:
0131
User Response
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions for that error event and restart the server.
3. Check the Lenovo support website for an applicable retain tip or firmware update that applies to
this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED
is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
•
806f040c-2005ffff : [PhysicalMemoryElementName] Disabled on Subsystem
[MemoryElementName]. (DIMM 5)
This message is for the use case when an implementation has detected that Memory has been Disabled.
May also be shown as 806f040c2005ffff or 0x806f040c2005ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
Appendix A. Integrated Management Module 2.1 (IMM2.1) error messages
401
Summary of Contents for NeXtScale n1200
Page 115: ...Chapter 6 Removing and replacing server components 101 ...
Page 117: ...Chapter 6 Removing and replacing server components 103 ...
Page 119: ...Chapter 6 Removing and replacing server components 105 ...
Page 135: ...Chapter 6 Removing and replacing server components 121 ...
Page 137: ...Chapter 6 Removing and replacing server components 123 ...
Page 139: ...Chapter 6 Removing and replacing server components 125 ...
Page 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Page 877: ......
Page 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...