User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling
the drive) b. Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server each
time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive
backplane (n = hard disk drive number)
•
806f010d-041fffff : The [StorageVolumeElementName] has been disabled due to a detected fault.
(SDHV Drive 16)
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
May also be shown as 806f010d041fffff or 0x806f010d041fffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0164
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling
the drive) b. Cable from the system board to the backplane
3. Replace the following components one at a time, in the order shown, restarting the server each
time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive
backplane (n = hard disk drive number)
•
806f010d-2b81ffff : The [StorageVolumeElementName] has been disabled due to a detected fault.
(FDIMM Stat)
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
May also be shown as 806f010d2b81ffff or 0x806f010d2b81ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
356
Lenovo NeXtScale nx360 M5 water-cooled technology tray Lenovo NeXtScale n1200 Enclosure Installation and Service Guide
Summary of Contents for NeXtScale n1200
Page 115: ...Chapter 6 Removing and replacing server components 101 ...
Page 117: ...Chapter 6 Removing and replacing server components 103 ...
Page 119: ...Chapter 6 Removing and replacing server components 105 ...
Page 135: ...Chapter 6 Removing and replacing server components 121 ...
Page 137: ...Chapter 6 Removing and replacing server components 123 ...
Page 139: ...Chapter 6 Removing and replacing server components 125 ...
Page 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Page 877: ......
Page 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...