May also be shown as 806f040c2581ffff or 0x806f040c2581ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix:
PLAT
ID:
0131
User Response
1. Make sure the DIMM is installed correctly.
2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions for that error event and restart the server.
3. Check the Lenovo support website for an applicable retain tip or firmware update that applies to
this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED
is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
One of the DIMMs :
•
806f0413-2582ffff : A PCI PERR has occurred on system [ComputerSystemElementName]. (PCIs)
This message is for the use case when an implementation has detected a PCI PERR.
May also be shown as 806f04132582ffff or 0x806f04132582ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0232
User Response
1. Check the PCI LED.
2. Reseat the affected adapters and riser cards.
3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster
solutions require specific code levels or coordinated code updates. If the device is part of a
cluster solution, verify that the latest level of code is supported for the cluster solution before you
update the code.
408
Lenovo NeXtScale nx360 M5 water-cooled technology tray Lenovo NeXtScale n1200 Enclosure Installation and Service Guide
Summary of Contents for NeXtScale n1200
Page 115: ...Chapter 6 Removing and replacing server components 101 ...
Page 117: ...Chapter 6 Removing and replacing server components 103 ...
Page 119: ...Chapter 6 Removing and replacing server components 105 ...
Page 135: ...Chapter 6 Removing and replacing server components 121 ...
Page 137: ...Chapter 6 Removing and replacing server components 123 ...
Page 139: ...Chapter 6 Removing and replacing server components 125 ...
Page 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Page 877: ......
Page 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...