1. If the processor or firmware was just updated, check the Lenovo support site for an applicable
service bulletin or firmware update that applies to this processor error.
2. (Trained service technician only) If there are multiple Processor’s, swap Processor’s to move
affected Processor to another Processor socket and retry. If problem follows the affected
Processor, or this is a single Processor processor. Inspect the processor socket on each
processor removal and replace system board first if the processor socket is damaged or mis-
aligned pins are found.
3. (Trained Service technician only) Inspect Processor socket on each Processor removal and
replace system board first if damaged or mis-aligned pins are found. Replace the system board.
•
W.3048006 [W.3048006]
Explanation:
UEFI has booted from the backup flash bank due to an Automatic Boot Recovery (ABR)
event. Automated Boot Recovery, Booting Backup UEFI Image
Severity
Warning
User Response
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies
to this error.
2. Update the primary UEFI image.
3. Replace the system board.
•
W.305000A [W.305000A]
Explanation:
An invalid date and time have been detected. RTC Date and Time Incorrect
Severity
Warning
User Response
Complete the following steps:
1. Check IMM/chassis event log. This event should immediately precede 0068002 error. Resolve
that event or any other battery related errors.
2. Use F1 Setup to reset date and time. If problem returns after a system reset, replace CMOS
battery.
3. If problem persists then check Lenovo support site for an applicable service bulletin or firmware
update that applies to this error.
4. (Trained service technician only) Replace the system board.
•
W.3058009 [W.3058009]
Explanation:
DRIVER HEALTH PROTOCOL: Missing Configuration. Requires Change Settings From F1.
DRIVER HEALTH PROTOCOL: Missing Configuration. Requires Change Settings From F1
Severity
Warning
User Response
Complete the following steps:
1. Go to F1 Setup > System Settings > Settings > Driver Health Status List and find a driver/
controller reporting Configuration Required status.
2. Search for the driver menu from System Settings and change settings appropriately.
3. Save settings and restart system.
•
W.305800A [W.305800A]
Appendix B. UEFI/POST diagnostic codes
707
Summary of Contents for NeXtScale n1200
Page 115: ...Chapter 6 Removing and replacing server components 101 ...
Page 117: ...Chapter 6 Removing and replacing server components 103 ...
Page 119: ...Chapter 6 Removing and replacing server components 105 ...
Page 135: ...Chapter 6 Removing and replacing server components 121 ...
Page 137: ...Chapter 6 Removing and replacing server components 123 ...
Page 139: ...Chapter 6 Removing and replacing server components 125 ...
Page 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Page 877: ......
Page 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...