2. Check the Lenovo support site for an applicable service bulletin or firmware update that applies
to this processor error.
3. (Trained technician only)Replace the system board
•
I.18010 [I.18010]
Explanation:
A processor stepping mismatch has been detected for one or more processor packages.
Processors of the same model have mismatched Stepping ID
Severity
Error
User Response
Complete the following steps:
1. Verify that matching processors are installed in the correct processor sockets. Correct any
mismatch found.
2. Check the Lenovo support site for an applicable service bulletin or firmware update that applies
to this processor error.
3. (Trained technician only)Replace the system board
•
I.2018002 [I.2018002]
Explanation:
The device found at Bus % Device % Function % could not be configured due to resource
constraints. The Vendor ID for the device is % and the Device ID is %. OUT_OF_RESOURCES (PCI Option
ROM)
Severity
Info
User Response
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat the adapter and any attached cables.
2. Check Lenovo support site for any applicable service bulletin or UEFI or adapter firmware
update that applies to this error. NOTE: It may be necessary to disable unused option ROMs
from UEFI F1 setup or ASU or using adapter manufacturer utilities so that adapter firmware can
be updated.
3. Move the adapter to a different slot. If a slot is not available or error recurs, replace the adapter.
4. If the adapter was moved to a different slot and the error did not recur, verify that this is not a
system limitation. Then replace the system board. Also, if this is not the initial installation and the
error persists after adapter replacement, replace the system board.
•
I.2018003 [I.2018003]
Explanation:
A bad option ROM checksum was detected for the device found at Bus % Device %
Function %. The Vendor ID for the device is % and the Device ID is %. ROM CHECKSUM ERROR
Severity
Error
User Response
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat the adapter and any attached cables.
2. Move the adapter to a different system slot, if available.
3. Check Lenovo support site for any applicable service bulletin or UEFI or adapter firmware
update that applies to this error. NOTE: It may be necessary to configure slot to Gen1 or to use
696
Lenovo NeXtScale nx360 M5 water-cooled technology tray Lenovo NeXtScale n1200 Enclosure Installation and Service Guide
Summary of Contents for NeXtScale n1200
Page 115: ...Chapter 6 Removing and replacing server components 101 ...
Page 117: ...Chapter 6 Removing and replacing server components 103 ...
Page 119: ...Chapter 6 Removing and replacing server components 105 ...
Page 135: ...Chapter 6 Removing and replacing server components 121 ...
Page 137: ...Chapter 6 Removing and replacing server components 123 ...
Page 139: ...Chapter 6 Removing and replacing server components 125 ...
Page 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Page 877: ......
Page 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...