Serviceable
No
Automatically notify support
No
Alert Category
System - Power On
SNMP Trap ID
24
CIM Information
Prefix:
PLAT
ID:
0107
User Response
No action; information only.
•
816f000d-0401ffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Comput HDD0 Pres)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0401ffff or 0x816f000d0401ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest
level.
3. Check the SAS cable.
4. Replace the hard disk drive.
•
816f000d-0402ffff : The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Comput HDD1 Pres)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0402ffff or 0x816f000d0402ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Appendix A. Integrated Management Module 2.1 (IMM2.1) error messages
535
Summary of Contents for NeXtScale n1200
Page 115: ...Chapter 6 Removing and replacing server components 101 ...
Page 117: ...Chapter 6 Removing and replacing server components 103 ...
Page 119: ...Chapter 6 Removing and replacing server components 105 ...
Page 135: ...Chapter 6 Removing and replacing server components 121 ...
Page 137: ...Chapter 6 Removing and replacing server components 123 ...
Page 139: ...Chapter 6 Removing and replacing server components 125 ...
Page 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Page 877: ......
Page 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...