background image

Manual IB-RD3741-C31

Type-C

 USB 3.1 (Gen 2) 2x2 RAID enclosure  

for 4x 2.5" or 3.5" SATA drives

Handbuch IB-RD3741-C31

Type-C

 USB 3.1 (Gen 2) 2x2 RAID Gehäuse  

für 4x 2,5" oder 3,5" SATA Laufwerke

Summary of Contents for IB-RD3741-C31

Page 1: ...Manual IB RD3741 C31 Type C USB 3 1 Gen 2 2x2 RAID enclosure for 4x 2 5 or 3 5 SATA drives Handbuch IB RD3741 C31 Type C USB 3 1 Gen 2 2x2 RAID Geh use f r 4x 2 5 oder 3 5 SATA Laufwerke...

Page 2: ...e type plate only Keep the device power unit away from humidity liquid vapour and dust Do not modify the device Do not connect the device during thunderstorms Approach specialist retailers if you requ...

Page 3: ...tion caused by components recycling circle interrupted This icon on product and packaging indicates that this product must not be disposed of as part of domestic waste In compliance with the Waste Ele...

Page 4: ...sf hrenden Komponenten vermeiden Steckkontakte nicht mit spitzen und metallischen Gegenst nden ber hren Verwendung nur in daf r vorgesehenen Umgebungen Ger t ausschlie lich mit Typenschildkonformen Ne...

Page 5: ...einigung der Ger te am besten mit trockenem Antistatiktuch durchf hren 7 Entsorgung des Ger tes Umweltverschmutzung Wiederverwertung nicht m glich M gliche Umweltbelastung durch Bestandteile Recycling...

Page 6: ...t your device s software may have a slightly different appearance or modified functionality than presented in this manual Package content 1x IB RD3741 C31 1x power cable 1x USB Type C to Type C cable...

Page 7: ...Supports SDXC UHS II 8 USB 3 0 Type A interface Supports data transfer rates with up to 5 Gbit s 9 Power LED Lighting blue device powered on Lighting orange standby mode OFF device switched off 10 SET...

Page 8: ...z 5 USB 3 1 Gen 2 Type C interface to host compu ter supports Power Delivery 3 0 with up to 60 W 6 Fan 80x80x20 mm 7 AC input power interface 100 240 V 8 Kensington Lock support 9 AC Power switch 15 F...

Page 9: ...MB s Silent operation by thermal controlled fan Energy saving by supporting sleep modus Plug Play Hot Swap Requirements Host PC with an available USB Type C port to ensure full dock functionality the...

Page 10: ...stallation Note Before installing the hard drive please disconnect the power plug from the outlet It may cause electric shock accident or malfunction When connecting the hard drive please note the ele...

Page 11: ...Press down the two tabs to detach the metal frame and remove it Take the transport cardboard out of the device if available Manual IB RD3741 C31...

Page 12: ...e provided screws to secure the handles to the 3 5 drives or the 2 5 drive carriers 3 5 HDD 2 5 HDD Slide the the 3 5 drives or the 2 5 drive carriers into the guide rails and push them downwards unti...

Page 13: ...from the device slightly press down the handle and pull it out Reinstall the metal frame that has been removed bevor Please make sure the bottom of the frame stays inside the track before closing the...

Page 14: ...s as follows When using RAID function drives with the same brand model and capacity is strongly recommended Setting or changing the RAID mode requires you to re format the drives This will erase all d...

Page 15: ...multaneously Striping is used to increase the performance of disk reads The multip le hard drives will write data in column effect If one drive in a striped set fails all of the data in the stripe set...

Page 16: ...RAID Mode Combination LED display status RAID configuration Manual IB RD3741 C31...

Page 17: ...Manual IB RD3741 C31...

Page 18: ...n the enclosure Make sure the PC is on and ready to go power on the device 2 The Device is built in 2 sets of RAID and each RAID is constructed by 2 drives There are two sets of Raid mode need to be s...

Page 19: ...can t press the button directly with your finger During setting the RAID mode use the supplied screwdriver to press the RAID confirmation button on the back of the unit Power on the device again and...

Page 20: ...RAID 1 array will take several hours depending on the drive capacity When the data has been restored the HDD LEDs at the front panel will turn a steady blue Note We recommend not turning off the power...

Page 21: ...oing the following steps At first click Start Execute on your PC and key in diskmgmt msc After that please press Return key 1 Start disk initialization Note Please enable GPT if the total capacity is...

Page 22: ...2 Create new partition and format disk Manual IB RD3741 C31...

Page 23: ...3 Drive format completed Manual IB RD3741 C31...

Page 24: ...unformatted drives are used they may first have to be initialized For initialisation do the following steps 1 Click Disk Utility icon 2 Drive initialisation 3 Choose the appropriated drive and click E...

Page 25: ...4 Drive format in process 5 Format completed Manual IB RD3741 C31...

Page 26: ...you want repeat the previous actions and enable GPT when initializing drives For macOS users the total capacity of more than 2 TB could be recognized only for the operation system is 10 4 1 1 Tiger o...

Page 27: ...it Please send back to the retail store immediately Operation Environment Temperature 0 35 C Humidity 90 RH The device is also working with computer notebook with USB 3 0 2 0 interfaces The full trans...

Page 28: ...n Ver nderungen eintreten die eine andere Funktions oder Vorgehensweise als in diesem Handbuch dargestellt haben k nnen Verpackungsinhalt 1x IB RD3741 C31 1x Stromkabel 1x USB Type C zu Type C Kabel S...

Page 29: ...igkeit in Abh ngigkeit von der gemesse nen Temperatur an Blau aus Der L fter l uft auf niedrigster Geschwindigkeit 6 Micro SD Kartenschacht Unterst tzt Micro SDXC UHS II Speicherkarten 7 SD Kartenscha...

Page 30: ...hluss zum Hostcom puter 6 L fter 80x80x20 mm 7 AC Stromanschluss 100 240 V 8 Kensington Lock Unterst tzung 9 AC Stromschalter 15 Frontt r 16 Laufwerksstatus HDD1 HDD2 HDD3 HDD4 Rot leuchtend Wiederher...

Page 31: ...eregelten L fter Energiesparend durch synchronisierten Standby Modus Plug Play HotSwap Anforderungen Hostcomputer mit freier USB Type C Schnittstelle um den vollen Funktionsumfang zugew hrleisten muss...

Page 32: ...ehlfunktionen zu vermeiden trennen Sie die Stromzufuhr des Ger tes bevor Sie die Lauf werke einsetzen oder entnehmen Beim Einsetzen der Laufwerke achten Sie auf m gliche elektrostatische Entladung da...

Page 33: ...r cken Sie die beiden Verriegelungen des Metallrahmens herunter und entnehmen Diesen Entnehmen Sie die Pappeinlagen Transportsicherung aus den Laufwerkssch chten falls vorhanden Handbuch IB RD3741 C31...

Page 34: ...se an die Enden der 3 5 Laufwerke oder an die Enden der 2 5 Laufwerkstr ger 3 5 HDD 2 5 HDD Schieben Sie die vorbereiteten Laufwerkstr ger in die Einsch be bis sie fest in den Anschl ssen ein rasten u...

Page 35: ...unten und l sen so die interne Verbindung um dann das Laufwerk entnehmen zu k nnen Setzen Sie den zuvor entnommenen Metallrahmen zur Sicherung der Laufwerke wieder ein und achten dabei darauf dass die...

Page 36: ...eb im RAID Modus empfehlen wir dringendst Laufwerke derselben Marke Modellversion und Kapa zit t zu verwenden Das Einstellen oder Wechseln des RAID Modus erfordert ein Neuformatieren der Festplatten D...

Page 37: ...eben RAID 0 Verbindet mehrere Laufwerke zu einem gro en virtuellen Laufwerk als eine logische Einheit Die Da ten werden parallel auf alle Laufwerke geschrieben was zu einer Steigerung der Datentransfe...

Page 38: ...2 Gruppen von RAIDs eingeteilt und jedes RAID wird mittels zweier Laufwerke gebildet Es gibt mehrere Arten von RAID Modi die vor der Verwendung richtig eingestellt werden m ssen Hierf r werden die Tas...

Page 39: ...Handbuch IB RD3741 C31...

Page 40: ...PC eingeschaltet und einsatzbereit ist schalten Sie das Ger t ein 2 Das Ger t ist aus 2 RAID Sets aufgebaut wobei jedes Set aus 2 Laufwerken besteht Somit m ssen Sie zwei Raid Modus Sets ordnungsgem e...

Page 41: ...it dem Finger dr cken Verwenden Sie w hrend der Einstellung des RAID Modus den mitgelieferten Schraubendreher um die RAID Best tigungstaste auf der R ckseite des Ger ts gedr ckt zu halten Schalten Sie...

Page 42: ...4 Die Wiederherstellung des RAID 1 Verbundes kann mehrere Stunden dauern abh ngig von der Laufwerksgr e Ist der Vorgang abgeschlossen erl schen die eben beschriebenen LED s und beide HDD LED s leuchte...

Page 43: ...abei bitte wie folgt vor F hren Sie Start und Ausf hren an Ihrem Windows Rechner aus und tippen Sie discmg mt mcs ein Dr cken Sie die Entertaste 1 Laufwerksinitialisierung starten Hinweis Aktivieren S...

Page 44: ...2 Neue Partition erstellen und formatieren Handbuch IB RD3741 C31...

Page 45: ...3 Laufwerksformatierung abgeschlossen Handbuch IB RD3741 C31...

Page 46: ...se unter Umst nden zun chst initialisiert werden Gehen Sie dabei bitte wie folgt vor 1 ffnen Sie das Festplattendienstprogramm 2 Initialisieren Sie das Laufwerk mithilfe des Dienstprogrammes 3 W hlen...

Page 47: ...4 Formatierung wird durchgef hrt 5 Nach Abschluss der Formatierung Handbuch IB RD3741 C31...

Page 48: ...10 4 1 1 oder h her auf Laufwerke gr er 2 TB zugreifen Die Rebuilddauer Wiederherstellung ist abh ngig von der Kapazit t der verwendeten Laufwerke Als Anhaltspunkt rechnen Sie bitte mit ungef hr 1 Stu...

Page 49: ...aratur ber Ihren H ndler veranlassen Arbeitsumgebung Temperatur 0 35 C Relative Luftfeuchtigkeit 90 Das Ger t funktioniert auch mit Computern die ber eine USB Type C USB 3 0 2 0 Schnittstelle verf gen...

Page 50: ...al may also not fully represent the product that you are using and are there for illustration purposes only RaidSonic Technology GmbH assumes no responsibility for any differences between the product...