background image

3 |  Wire an optional wire-in transformer

For systems using an optional wire-in transformer, wire the transformer as shown in 

this section.

2 | Installation

Dimensions

16 in. x 16 in. x 3.5 in. (41 cm x 41 cm x 9 cm)

Color

B8103-White, D8103-Grey

Compatible tamper switches

D110 (P/N: 4998137947) or 

ICP-EZTS (P/N: F01U217038)

Compatible locksets (optional)

D101-448478D (Key #1358)

D101F-43157D (Key #203)

4 |  Specifications

Copyright

This document is the intellectual property of Bosch Security Systems, Inc. and is 

protected by copyright. All rights reserved.

Trademarks

All hardware and software product names used in this document are likely to be 

registered trademarks and must be treated accordingly.

Bosch Security Systems, Inc. product manufacturing dates

Use the serial number located on the product label and refer to the Bosch Security 

Systems, Inc. website at http://www.boschsecurity.com/datecodes/.

1 | Overview

1

12

2

7

2

4

4

8

5

6

9

10

11

3

This enclosures can be used for residential fire and burglary installations and 

commercial burglary applications that do not require attack resistance.

Callout ― Description

Callout ― Description

1 ― Point chart label

7 ― Skirt mounting hole

2 ― Module mounting locations (4)

8 ― Battery mounting locations (2)

3 ― Tamper switch mounting location

9 ― Back of the control panel

4 ― Mounting hole locations (5)

10 ― Mounting skirt hook openings (2)

5 ― Mounting skirt hooks (2)

11 ― Screw tab

6 ― Control panel mounting location

12 ― Lockset

2

L

N

3

4

USB POWER

STATUS

B

A

S

E

L

I

N

K

T

ETHERNET

USB

EARTH GROUND

COMMON

BATTERY ( 

- )

+ AUX POWER

BATTERY ( + )

CLASS 2 

16.5 VAC 40 VA 60 Hz

TRANSFORMER

10

9

8

7

6

5

4

3

2

1

WARNING! 

Multi-Battery 

installation requires

Model D122 or D122L 

Dual Battery Harness. 

Improper installation 

can be a fire hazard

.

Low 12.1 VDC
Load Shed 10.2 VDC

OUTPUT

B (2)

OUTPUT

A (1)

OUTPUT

C (3)

1

Callout ― Description

1 ― Low voltage AC
2 ― Ground wire connection
3 ― AC IN
4 ― Wire tie the AC IN wires to the enclosure lance