Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps:
1. Check the event log of XClarity Controller for any fan or cooling-related issues or power-related
issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in
place, clean, and correctly installed.
3. Make sure that the room temperature is within operating specifications.
•
FQXSPCA0019N: Sensor [SensorElementName] has transitioned to non-recoverable from a less
severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0524
User Action:
Complete the following steps:
1. Check the event log of XClarity Controller for any fan- or cooling-related issues or power-related
issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in
place, clean, and correctly installed.
3. Make sure that the room temperature is within the range of operating specifications.
•
FQXSPCA2002I: Numeric sensor [NumericSensorElementName] going low (lower critical) has
deasserted.
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Fan Failure
SNMP Trap ID: 11
CIM Prefix: PLAT CIM ID: 0481
User Action:
Information only; no action is required
•
FQXSPCA2007I: Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has deasserted.
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has deasserted.
28
ThinkSystem SN550 V2 Messages and Codes Reference
Summary of Contents for 7X16
Page 1: ...ThinkSystem SN550 V2 Messages and Codes Reference Machine Type 7X16 ...
Page 4: ...ii ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 140: ...136 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......