This message is for the use case when an implementation has detected that an Array Failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0176
User Action:
Complete the following steps:
1. Replace any hard disk drive that is indicated by a lit status LED.
2. Re-create the array.
3. Restore the data from a backup.
•
FQXSPSD2000I: The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Drive has been Removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0163
User Action:
Complete the following steps until the problem is solved:
1. If drive was intentionally removed, make sure that there is a filler in the drive bay.
2. Make sure that the drive is correctly seated.
3. If drive is correctly seated, replace the drive.
•
FQXSPSD2001I: The [StorageVolumeElementName] has been enabled.
This message is for the use case when an implementation has detected a Drive was Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0167
User Action:
Information only; no action is required
•
FQXSPSD2002I: Failure no longer Predicted on [StorageVolumeElementName] for array
[ComputerSystemElementName].
This message is for the use case when an implementation has detected an Array Failure is no longer
Predicted.
Severity: Info
Serviceable: No
Automatically notify Support: No
.
107
Summary of Contents for 7X16
Page 1: ...ThinkSystem SN550 V2 Messages and Codes Reference Machine Type 7X16 ...
Page 4: ...ii ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 140: ...136 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......