Table 2. Events organized by severity (continued)
Event ID
Message String
Severity
FQXSPUP0002I
A firmware or software change occurred on system
[ComputerSystemElementName].
Informational
FQXSPUP4001I
Flash of [arg1] from [arg2] succeeded for user [arg3] .
Informational
FQXSPUP4002I
Flash of [arg1] from [arg2] failed for user [arg3].
Informational
FQXSPWD0000I
Watchdog Timer expired for [WatchdogElementName].
Informational
FQXSPWD0001I
Reboot of system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0002I
Powering off system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0003I
Power cycle of system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0004I
Watchdog Timer interrupt occurred for [WatchdogElementName].
Informational
FQXSPBR4001I
Running the backup Management Controller [arg1] main application.
Warning
FQXSPCA0007J
Numeric sensor [NumericSensorElementName] going high (upper
non-critical) has asserted.
Warning
FQXSPCA0015J
Sensor [SensorElementName] has transitioned from normal to non-
critical state.
Warning
FQXSPDM4002I
Device [arg1] VPD is not valid.
Warning
FQXSPEA0001J
Sensor [SensorElementName] has transitioned from normal to non-
critical state.
Warning
FQXSPIO0014J
Bus [SensorElementName] is operating in a degraded state.
Warning
FQXSPMA0010J
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName] Throttled.
Warning
FQXSPMA0011G
Memory Logging Limit Reached for [PhysicalMemoryElementName]
on Subsystem [MemoryElementName].
Warning
FQXSPNM4010I
DHCP[[arg1]] failure, no IP address assigned.
Warning
FQXSPNM4032I
DHCPv6 failure, no IP address assigned.
Warning
FQXSPPP4009I
The measured power value exceeded the power cap value.
Warning
FQXSPPP4010I
The new minimum power cap value exceeded the power cap value.
Warning
FQXSPPU0002G
The Processor [ProcessorElementName] is operating in a Degraded
State.
Warning
FQXSPPW0003G
Failure predicted on [PowerSupplyElementName].
Warning
FQXSPPW0006I
[PowerSupplyElementName] has lost input.
Warning
FQXSPPW0031J
Numeric sensor [NumericSensorElementName] going low (lower non-
critical) has asserted.
Warning
FQXSPPW0057J
Sensor [SensorElementName] has transitioned from normal to non-
critical state.
Warning
FQXSPPW0101J
Redundancy Degraded for [RedundancySetElementName] has
asserted.
Warning
19
Summary of Contents for 7X16
Page 1: ...ThinkSystem SN550 V2 Messages and Codes Reference Machine Type 7X16 ...
Page 4: ...ii ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 140: ...136 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......