User Action:
Complete the following steps:
1. Adjust the room temperature to ensure it is within server environmental specification.
2. If the problem still exists, check XCC Web GUI to check if the temporature value is still higher than
system specfication in the publication.
3. Please contact Lenovo Support.
•
FQXSPCA0011N: Numeric sensor [NumericSensorElementName] going high (upper non-
recoverable) has asserted.
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor
going high has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0498
User Action:
Complete the following steps:
1. Adjust the room temperature to ensure it is within server environmental specification.
2. If the problem still exists, check XCC Web GUI to check if the temporature value is still higher than
system specfication in the publication.
3. Please contact Lenovo Support.
•
FQXSPCA0015J: Sensor [SensorElementName] has transitioned from normal to non-critical state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
critical from normal.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Temperature
SNMP Trap ID: 12
CIM Prefix: PLAT CIM ID: 0520
User Action:
Complete the following steps:
1. Check the event log of XClarity Controller for any fan- or cooling-related issues or power-related
issues.
2. Make sure that the airflow is not obstructed and that fillers are in place and correctly installed.
3. Make sure that the room temperature is within the range of operating specifications.
•
FQXSPCA0017M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
27
Summary of Contents for 7X16
Page 1: ...ThinkSystem SN550 V2 Messages and Codes Reference Machine Type 7X16 ...
Page 4: ...ii ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 140: ...136 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......