Table 2. Events organized by severity (continued)
Event ID
Message String
Severity
FQXSPNM4031I
IPv6 static address of network interface modified from [arg1] to [arg2]
by user [arg3].
Informational
FQXSPNM4033I
Telnet port number changed from [arg1] to [arg2] by user [arg3].
Informational
FQXSPNM4034I
SSH port number changed from [arg1] to [arg2] by user [arg3].
Informational
FQXSPNM4035I
Web-HTTP port number changed from [arg1] to [arg2] by user [arg3].
Informational
FQXSPNM4036I
Web-HTTPS port number changed from [arg1] to [arg2] by user [arg3].
Informational
FQXSPNM4037I
CIM/XML HTTP port number changed from [arg1] to [arg2] by user
[arg3].
Informational
FQXSPNM4038I
CIM/XML HTTPS port number changed from [arg1] to [arg2] by user
[arg3].
Informational
FQXSPNM4039I
SNMP Agent port number changed from [arg1] to [arg2] by user
[arg3].
Informational
FQXSPNM4040I
SNMP Traps port number changed from [arg1] to [arg2] by user [arg3].
Informational
FQXSPNM4041I
Syslog port number changed from [arg1] to [arg2] by user [arg3].
Informational
FQXSPNM4042I
Remote Presence port number changed from [arg1] to [arg2] by user
[arg3].
Informational
FQXSPNM4043I
SMTP Server set by user [arg1] to [arg2]:[arg3].
Informational
FQXSPNM4044I
Telnet [arg1] by user [arg2].
Informational
FQXSPNM4045I
DNS servers set by user [arg1]: UseAdditionalServers=[arg2],
PreferredDNStype=[arg3], IPv4Server1=[arg4], IPv4Server2=[arg5],
IPv4Server3=[arg6], IPv6Server1=[arg7], IPv6Server2=[arg8],
IPv6Server3=[arg9].
Informational
FQXSPNM4046I
LAN over USB [arg1] by user [arg2].
Informational
FQXSPNM4047I
LAN over USB Port Forwarding set by user [arg1]: ExternalPort=
[arg2], USB-LAN port=[arg3].
Informational
FQXSPNM4048I
PXE boot requested by user [arg1].
Informational
FQXSPNM4049I
User [arg1] has initiated a TKLM Server Connection Test to check
connectivity to server [arg2].
Informational
FQXSPNM4050I
User [arg1] has initiated an SMTP Server Connection Test.
Informational
FQXSPNM4051I
User [arg1] has set the SMTP Server reverse-path to [arg2].
Informational
FQXSPNM4052I
DHCP specified hostname is set to [arg1] by user [arg2].
Informational
FQXSPNM4053I
DNS discovery of Lenovo XClarity Administrator has been [arg1] by
user [arg2].
Informational
FQXSPNM4054I
The hostname from DHCP is [arg1] by user [arg2].
Informational
FQXSPNM4055I
The hostname from DHCP is invalid.
Informational
FQXSPNM4056I
The NTP server address [arg1] is invalid.
Informational
FQXSPNM4057I
Security: IP address: [arg1] had [arg2] login failures, it will be blocked
to access for [arg3] minutes.
Informational
11
Summary of Contents for 7X16
Page 1: ...ThinkSystem SN550 V2 Messages and Codes Reference Machine Type 7X16 ...
Page 4: ...ii ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 140: ...136 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......