Table 2. Events organized by severity (continued)
Event ID
Message String
Severity
FQXSPIO0003N
A diagnostic interrupt has occurred on system
[ComputerSystemElementName].
Error
FQXSPIO0004L
A bus timeout has occurred on bus [SensorElementName].
Error
FQXSPIO0006N
A software NMI has occurred on system
[ComputerSystemElementName].
Error
FQXSPIO0007N
A PCI PERR has occurred on system
[ComputerSystemElementName].
Error
FQXSPIO0008N
A PCI SERR has occurred on system
[ComputerSystemElementName].
Error
FQXSPIO0011N
An Uncorrectable Error has occurred on [SensorElementName].
Error
FQXSPIO0013N
A Fatal Bus Error has occurred on bus [SensorElementName].
Error
FQXSPIO0015M
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Error
FQXSPMA0002N
Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Error
FQXSPMA0005N
Subsystem [MemoryElementName] has insufficient memory for
operation.
Error
FQXSPMA0007L
Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Error
FQXSPMA0008N
Uncorrectable error detected for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
Error
FQXSPMA0012M
An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Error
FQXSPMA0013N
The System [ComputerSystemElementName] has detected no
memory in the system.
Error
FQXSPOS4002I
Watchdog [arg1] Failed to Capture Screen.
Error
FQXSPOS4003I
Platform Watchdog Timer expired for [arg1].
Error
FQXSPOS4010I
OS Crash Video Capture Failed.
Error
FQXSPPU0001N
An Over-Temperature Condition has been detected on
[ProcessorElementName].
Error
FQXSPPU0003N
[ProcessorElementName] has Failed with IERR.
Error
FQXSPPU0004M
[ProcessorElementName] has Failed with FRB1/BIST condition.
Error
FQXSPPU0009N
[ProcessorElementName] has a Configuration Mismatch.
Error
FQXSPPU0011N
An SM BIOS Uncorrectable CPU complex error for
[ProcessorElementName] has asserted.
Error
FQXSPPW0002L
[PowerSupplyElementName] has Failed.
Error
FQXSPPW0007L
[PowerSupplyElementName] has a Configuration Mismatch.
Error
FQXSPPW0035M
Numeric sensor [NumericSensorElementName] going low (lower
critical) has asserted.
Error
21
Summary of Contents for 7X16
Page 1: ...ThinkSystem SN550 V2 Messages and Codes Reference Machine Type 7X16 ...
Page 4: ...ii ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 6: ...2 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 140: ...136 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 204: ...200 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 208: ...204 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 210: ...206 ThinkSystem SN550 V2 Messages and Codes Reference ...
Page 211: ......
Page 212: ......