2R4/2R5/2R6
6-126
6.Press the [Start] key to set the setting value.
7.Measure the distance "D" and "E" from the top edge of black belt 1 to the bottom edge of black
belt 3 on the adjustment original at two positions.
Measurement procedure
1) Measure the distance "D" and "E" between two points as follows. (D: Measure the distance
from the leading edge to the trailing edge of black belt 3 on the adjustment original at 30mm of
the left edge and deduct A. E: Measure the distance from the leading edge to the trailing edge
of black belt 3 on the adjustment original at 180mm of the left edge and deduct C.)
2) Apply the following formula for the values obtained: (D/2+E/2)
8.Enter the value solved in "Sub Scan" using the [
Ż
] [
Ź
] keys keys.
9.Press the [Start] key to set the setting value.
Figure 6-20
Original for adjustment
(P/N: 7505000107)
F
A
B
C
D
E
30mm
105mm
180mm
21mm
Leading edge
Left edge
[Dist1] = (A+B+C)/3
[Dist2] = F
[Dist3] = D/2+E/2
Black belt 1
Black belt 2
Black belt 3