Uses the specified originals and automatically adjusts the following items in the scanner and the
DP scanning sections.
Scanner section: Original size magnification, leading edge timing, center line, chromatic aberra-
tion in main/sub scanning direction, MTF correction, color/monochrome input gamma, color cor-
rection matrix automatic adjustment
DP scanning section: Original size magnification, leading edge timing and center line MTF cor-
rection, Input gamma, automatic adjustment of color correction matrix
Purpose
Automatically adjusts the scanner and the DP scanning sections.
U411
Scanner auto adjustment
(Message: Auto Adj Scn)
Items
Contents
Original for adjustment
(P/N)
Table (Chart
A)
Automatically adjusts the table scanning.
Magnification in the sub-scanning direction
Leading edge timing
Center line
Chromatic aberration in the main scanning
direction
Input gamma in monochrome mode
Input gamma in color mode
Color correction matrix
7505000107
DP
FU(ChartB)
DP
FD(ChartB)
Execute the 1st side automatic adjustment
in the DP scanning section.
Execute the 2nd side automatic adjustment
in the DP scanning section.
Magnification in the sub-scanning direction
Leading edge timing
Center line
Trailing edge timing
7505000106
DP
FU(ChartA)
Execute the 1st side automatic adjustment
in the DP scanning section.
Input gamma in monochrome mode
Input gamma in color mode
Color correction matrix
7505000107
All
Automatically adjusts the DP scanning
after the automatic adjustment of the table
scanning.
Automatic adjustment in the scanning sec-
tion.
7505000107
7505000106
Target
Set-up for obtaining the target value
7505000107