2R4/2R5/2R6
6-290
Contents
Sets the fuser temperature.
Purpose
Normally no need to change. However, change the setting as corrective measures for paper curl,
creases and fusing failure on thick paper.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Setting: Center
1.Select the item to set.
2.By using the [+] [-] keys or the numeric keys, change the setting value.
*1
:35ppm model,
*2
: 40ppm model
3.Press the [Start] key to set the setting value.
Setting: Edge
1.Select the item to set.
2.By using the [+] [-] keys or the numeric keys, change the setting value.
U161
Fuser temperature adjustment
(Message: Adjust Fuser Control Temperature)
Items
Contents
Center
Set the center thermistor temperature.
Edge
Sets the edge thermistor control temperature.
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
Pressure Start
Sets the temperature to start
pressing
0 to 200
30
1°C
Drive Start
Sets the drive start temperature 0 to 200
100
1°C
Ready
Sets the Ready temperature
100 to 200
150
*1
/160
*2
1°C
Steady
Sets the secondary stability
temperature
100 to 200
155
*1
/165
*2
1°C
Printing
Set the temperature during
printing
100 to 200
160
*1
/170
*2
1°C
Waiting
Set the standby temperature
100 to 200
150
*1
/160
*2
1°C
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
Ready
Sets the Ready temperature
100 to 200
105
*1
/115
*2
1°C
Steady
Sets the secondary stability
temperature
100 to 200
140
*1
/150
*2
1°C