2R4/2R5/2R6
6-359
Contents
Sets the operation of the color registration correction and transfer belt speed correction.
Also, sets the execution condition of the color registration correction by the LSU temperature
variation.
Purpose
If the color registration is unstable due to the sensor failure, etc., set it to off to temporarily fix the
control value.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Setting: Color Regist
1.Select the item to set.
* :Initial setting: On
2.Press the [Start] key to set the setting value.
Setting: Timing
1.By using the [+] [-] keys or the numeric keys, change the setting value.
2.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U467
Color registration correction operation setting
(Message: Set Color Regist Adjustment Mode)
Items
Contents
Color Regist
Sets the color registration correction
Timing
Execute the color registration correction if the LSU temperature changes
by the specified value after the previous correction
Items
Contents
On
Permitting the color registration correction operation
Off
Prohibiting the color registration correction operation
Items
Contents
Setting
range
Initial setting
LSU Temp
Execution condition by the LSU temperature
variation
2 to 20
10
Summary of Contents for TASKalfa 306ci
Page 36: ...2R4 2R5 2R6 2 6 35 ...
Page 191: ...2R4 2R5 2R6 2 6 190 ...
Page 233: ...2R4 2R5 2R6 6 232 ...
Page 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Page 280: ...2R4 2R5 2R6 6 279 ...