2R4/2R5/2R6
6-66
Contents
Display and clear the transfer counts for the transfer high-voltage output correction etc.
Purpose
Verify the primary/secondary transfer unit counts after replacing Also, clear the counts after
replacement
Method
1.Press the [Start] key.
* : The transfer counter value appears.
Setting: Mid(Cnt)
* :Clear only. This cannot be changed.
1.Select [Clear].
2.Press the [Start] key to set the counter value.
Setting: 2nd(Cnt)
1.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
2.Press the [Start] key to set the counter value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U127
Clearing the transfer count
(Message: Clr Trans Cnt)
Items
Contents
Mid(Cnt)
Displays or clears the primary transfer counter
2nd(Cnt)
Displays or clears the secondary transfer counter