2R4/2R5/2R6
6-55
Contents
Set the secondary transfer control voltage.
Purpose
Change setting if a failure such as faint image, etc. occurs.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Setting: Light/Normal1
1.Select the item to set.
* :The screen for setting is displayed.
2.Select the item to set.
3.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
1st
U106
Secondary transfer voltage adjustment
(Message: 2nd TC Output)
Items
Contents
Light/Normal1
Transfer control value for Light and Normal1
Normal2/3
Transfer control value for Normal 2 / 3
Light/Normal123
Transfer control value for Light to Normal1,2,3
Heavy1
Transfer control value for Normal 1 / 3
Heavy2/3
Transfer control value for Heavy 2 / 3
OHP
Transfer control value for Transparency
Light-Normal3
Transfer control value for Light to Normal3
Bias
Bias setting
High Altitude
High altitude correction control setting (2nd side correction)
Paper End
Turning off the secondary transfer at the paper end
Items
Contents
1st
1st side transfer control value at full speed
2nd
2nd side transfer control value at full speed
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
W<160
Setting paper width less than 160
0 to 2000
600
-
160<=W<210
Setting paper width of 160 or more and
less than 210
0 to 2000
400
-