2R4/2R5/2R6
6-82
Contents
Adjusts touch panel detecting positions.
Purpose
Correct and confirm the touch panel detecting positions, when the panel PWB or the operation
panel is replaced or if the detecting positions are not aligned.
Method
1.Press the [Start] key.
2.Select the item to execute.
3.Press the [Start] key.
* :The screen for executing is displayed.
Method: Initialize
1.Press the center of "+".
2.Repeat 3 times.
3.After finishing setting, the [Check] screen is
automatically displayed.
Method: Check
4.Press the indicated three "+", and then check
the display position.
* :If out of the specified value, select [Initial-
ize] and press the [Start] key to return to
Step. 1.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U201
Initializing the touch panel
(Message: Init Touch Panel)
Items
Contents
Initialize
Automatically corrects the touch panel display position
Check
Checks the touch panel display position
Init Touch Panel
U201
01 Initialize
02 Check
+
+
+