2R4/2R5/2R6
6-285
Contents
Mode selection for the operation to remove overcharged toner in the developer unit (Toner apply-
ing mode). Also, sets the operation to take toner accumulated on the developer blade back to the
developer unit (vibration motor control).
Purpose
Change the setting to reduce the toner applying amount. Execute to change the vibration motor
control frequency.
* :Density is lowered if overcharged toner stays in the developer unit.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Setting: Mode
1.Select the item to set.
* :Initial setting: On
2.Press the [Start] key to set the setting value.
Setting: Drum T7
1.By using the [+] [-] keys or the numeric keys, change the setting value.
2.Press the [Start] key to set the setting value.
U147
Setting the toner applying mode
(Message: Set Toner Apply Mode)
Items
Contents
Mode
Sets the toner applying mode.
Drum T7
Sets the toner applying width at the cleaning mode.
Developing T7
Sets the upper limit of the toner applying amount for each operation
mode.
Motor
Sets the vibration motor operation.
Items
Contents
On
Sets the toner applying operation with the normal amount.
Off
Sets the toner applying operation with less than the normal amount.
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
Value
Sets the toner applying width at the
cleaning mode.
0 to 25
150
(Indicated as
15.0)
0.1mm