Displays/changes the developer bias set values or sets high altitude mode.
Purpose
Execute to check/change the developer bias set values.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
*1: 40 ppm model only
Setting: Sleeve DC
1.Select the item to set.
2.By using the [+] [-] keys or the numeric keys, change the setting value.
*1
:35ppm model,
*2
: 40ppm model
3.Press the [Start] key to set the setting value.
U140
Developer bias adjustment
(Message: Adjust Developing Bias)
Items
Contents
Sleeve DC
Set the developer sleeve roller DC bias.
Sleeve AC
Set the developer sleeve roller AC bias.
Mag DC
Set the developer magnet roller DC bias.
Mag AC
*1
Set the developer magnet roller AC bias.
Sleeve Freq
Set the developer sleeve roller frequency.
Sleeve Duty
Set the developer sleeve roller duty.
Mag Duty
Set the developer magnet roller duty.
AC Calib
*1
Execute and set AC Calibration
Image Preference
Sets the toner density
Altitude Adjustment
Sets the altitude adjustment mode
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
C
Sets the cyan
0 to 350
200
*1
90
*2
-
M
Sets the magenta
0 to 350
200
*1
90
*2
-
Y
Sets the yellow
0 to 350
200
*1
90
*2
-
K
Sets the black
0 to 350
200
*1
90
*2
-