2R4/2R5/2R6
6-369
Contents
Execute the LSU cleaning by operating the LSI cleaning motor. Also, sets the cleaning operation
interval and timing to enter the operation.
Method
1.Press the [Start] key.
2.Select the item to execute.
Method: Execute
1.Press the [Start] key.
* :The LSU slit glass is cleaned.
Method: Cycle
1.Select the item to set.
Setting: Cnt
1.By using the [+] [-] keys or the numeric keys, change the setting value.
* :Settable in 100-sheet increments. (Actual control x5 (=500 sheets))
2.Press the [Start] key to set the setting value.
Setting: Timing
1.Select the item to set.
* :Initial setting: Print End
2.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U474
Checking the LSU cleaning
(Message: Check LSU Cleaning Operation)
Items
Contents
Execute
Executes the cleaning operation.
Cycle
Sets the cleaning operation.
Items
Contents
Setting
range
Initial setting
Cnt
Sets the cleaning cycle.
0 to 5000
1000
Timing
Sets the LSU cleaning timing
Print /
Print End
Print End
setting
Contents
Clean during job
Print End
Clean after completing the job