2R4/2R5/2R6
6-53
Contents
Set the primary transfer control voltage
Purpose
Change setting if a failure such as faint image, etc. occurs.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Setting: Normal
1.Select the item to set.
2.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
3.Press the [Start] key to set the setting value.
Setting: Add Color
1.Select the item to set.
2.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
3.Press the [Start] key to set the setting value.
U101
Primary transfer voltage adjustment
(Message: 1st TC Output)
Items
Contents
Normal
Set the primary transfer voltage
Add Color
Sets 2nd side additional value
Add Color 2nd
Sets 2nd side additional value.
Surround Correct
Setting the environmental correction
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
Full
Yellow primary transfer voltage (full
speed)
0 to 400
70
-
Half
Yellow primary transfer voltage (half
speed)
0 to 400
43
-
3/4
Yellow primary transfer voltage (3/4
speed)
0 to 400
56
-
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
C
Sets the additional value (Cyan)
-200 to 200
-4
-
M
Sets the additional value (Magenta)
-200 to 200
-4
-
Y
Sets the additional value (Yellow)
-200 to 200
0
-
K
Sets the additional value (Black)
-200 to 200
17
-
B/W
Monochrome mode (toner applying
amount)
-200 to 200
-27
-