2R4/2R5/2R6
6-326
Contents
Sets the print interval at high coverage.
Purpose
Changes the print interval at high coverage.
Setting
1.Press the [Start] key.
2.Select the item to set.
3.By using the [+] [-] keys or the numeric keys, change the setting value.
4.Press the [Start] key to set the setting value.
Setting: Threshold
1.Select the item to set.
2.By using the [+] [-] keys or the numeric keys, change the setting value.
3.Press the [Start] key to set the setting value.
Method: Rate
* :Display each setting values.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U325
Paper interval setting
(Message: Set Paper Interval (Add Toner))
Items
Contents
Setting range
Initial
setting
Interval
Sets On/Off of print interval at high coverage.
On/Off
Off
Average
Set the average number of sheets (parameter)
1 to 255
100
Threshold
Sets the coverage threshold to start lowering.
-
-
Rate
Displays the down rate
-
-
Items
Contents
Setting range
Initial
setting
C
Coverage threshold to start lowering for Cyan
1 to 100
15
M
Coverage threshold to start lowering for Magenta
1 to 100
15
Y
Coverage threshold to start lowering for Yellow
1 to 100
15
K
Coverage threshold to start lowering for Black
1 to 100
20
Items
Contents
Setting range
Initial
setting
C
Cyan down rate
50 to 100
100
M
Magenta down rate
50 to 100
100
Y
Yellow down rate
50 to 100
100
K
Black down rate
50 to 100
100