2R4/2R5/2R6
6-143
Setting: System
1.Select the item to set.
2.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
3.Press the [Start] key to set the setting value.
Supplement
Test copy of the original is available by pressing the [System Menu/Counter] key as interruption
copy mode when executing this maintenance mode.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Execute the LSU cleaning by operating the LSI cleaning motor. Also, sets the cleaning operation
interval.
Method
1.Press the [Start] key.
2.Select the item to execute.
Method: Execute
1.Press the [Start] key.
* :The LSU slit glass is cleaned.
Setting: Cycle
1.Select the item to set.
2.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
*1
: Set in 100 sheet increments
3.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Items
Contents
Setting
range
Initial setting
Y
Compression rate of the brightness
1 to 100
90(%)
CbCr
Compression rate of the color difference
1 to 100
90(%)
U474
Checking the LSU cleaning
(Message: Chk LSU Cleaning)
Items
Contents
Execute
Executes the cleaning operation.
Cycle
Sets the cleaning cycle.
Items
Contents
Setting range
Initial set-
ting
Cnt
Sets the cleaning cycle.
0 to 5000
*1
1000
Timing
Sets the LSU cleaning timing
Print (during job)
Print End (after complet-
ing job)
Print End