2R4/2R5/2R6
6-281
Setting: Sleeve AC
1.Select the item to set.
2.By using the [+] [-] keys or the numeric keys, change the setting value.
3.Press the [Start] key to set the setting value.
Setting: Mag DC
1.Select the item to set.
2.By using the [+] [-] keys or the numeric keys, change the setting value.
*1
:35ppm model,
*2
: 40ppm model
3.Press the [Start] key to set the setting value.
Setting: Mag AC
1.Select the item to set.
2.By using the [+] [-] keys or the numeric keys, change the setting value.
3.Press the [Start] key to set the setting value.
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
C
Sets the cyan
100 to 170
145
-
M
Sets the magenta
100 to 170
145
-
Y
Sets the yellow
100 to 170
145
-
K
Sets the black
100 to 170
145
-
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
C
Sets the cyan
0 to 750
510
*1
400
*2
-
M
Sets the magenta
0 to 750
510
*1
400
*2
-
Y
Sets the yellow
0 to 750
510
*1
400
*2
-
K
Sets the black
0 to 750
510
*1
400
*2
-
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
C
Sets the cyan
100 to 270
250
-
M
Sets the magenta
100 to 270
250
-
Y
Sets the yellow
100 to 270
250
-
K
Sets the black
100 to 270
250
-