2R4/2R5/2R6
6-256
Setting: Set DC Bias Base
1.Displays the current setting.
*1
: 35 ppm model only,
*2
: 40 ppm model
Refer: Chk Current
1.Displays the current setting.
Setting: Set AC Gain
1.Select the item to set.
* :Initial setting: Auto
2.Press the [Start] key to set the setting value.
Items
Contents
DC1 Bias Base(C)
Cyan main charge DC bias base value (Full speed)
DC1 Bias Base 3/4(C)
Cyan main charge DC bias base value (3/4 speed)
DC1 Bias Base Half(C)
Cyan main charge DC bias base value (Half speed)
DC1 Bias Base(M)
Magenta main charge DC bias base value (Full speed)
DC1 Bias Base 3/4(M)
Magenta main charge DC bias base value (3/4 speed)
DC1 Bias Base
Half(M)
Magenta main charge DC bias base value (Half speed)
DC1 Bias Base(Y)
Yellow main charge DC bias base value (Full speed)
DC1 Bias Base 3/4(Y)
Yellow main charge DC bias base value (3/4 speed)
DC1 Bias Base Half(Y)
Yellow main charge DC bias base value (Half speed)
DC1 Bias Base(K)
Black main charge DC bias base value (Full speed)
DC1 Bias Base 3/4(K)
Black main charge DC bias base value (3/4 speed)
DC1 Bias Base Half(K)
Black main charge DC bias base value (Half speed)
Items
Contents
C
Cyan inflow current
M
Magenta inflow current
Y
Yellow inflow current
K
Black inflow current
Items
Contents
Auto
Automatic environmental setting (default)
Mode1
In case of C2201/C2202 errors occurrence (multiplication value 0.95)
Mode2
If the horizontal lines appear in the main charge roller circumference
interval (Multiplication value 1.05)
Mode3
In case of the level where the C2201/C2202 errors occur and horizontal
lines in the main charge roller circumference interval are pointed out in
Summary of Contents for TASKalfa 306ci
Page 36: ...2R4 2R5 2R6 2 6 35 ...
Page 191: ...2R4 2R5 2R6 2 6 190 ...
Page 233: ...2R4 2R5 2R6 6 232 ...
Page 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Page 280: ...2R4 2R5 2R6 6 279 ...