2R4/2R5/2R6
6-274
Contents
Displays the drum drive distance counter.
Purpose
Execute to displays the drum drive distance counter.
Method
1.Press the [Start] key.
* :Displays the count.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Display and clear the transfer counts for the transfer high-voltage output correction etc.
Purpose
Verify the primary/secondary transfer unit counts after replacing Also, clear the counts after
replacement
Method
1.Press the [Start] key.
* : The transfer counter value appears.
Setting: Mid Trans(Cnt)
* :Clear only. This cannot be changed.
1.Select [Clear].
2.Press the [Start] key to set the counter value.
Setting: 2nd Trans(Cnt)
1.By using the [+] [-] keys or the numeric keys, change the setting value.
2.Press the [Start] key to set the counter value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U120
Drum drive distance counter
(Message: Drum Driving Distance Counter)
Items
Contents
C
Displays the cyan drum drive distance counter
M
Displays the magenta drum drive distance counter
Y
Displays the yellow drum drive distance counter
K
Displays the black drum drive distance counter
U127
Clearing the transfer count
(Message: Clear Transfer Roller Counter)
Items
Contents
Mid Trans(Cnt)
Displays or clears the primary transfer counter
2nd Trans(Cnt)
Displays or clears the secondary transfer counter