Corrects the color registration data.
Purpose
Execute when replacing the laser scanner unit.
* :Make sure to execute U464 Calib before executing this maintenance mode.
Method
1.Press the [Start] key.
2.Select the item to set.
* :Select [Auto] to output the automatic adjustment chart.
* :Select [Manual] to enter the setting display.
Method: Auto
1.Select the item to execute.
Method: Print
1.Press the [Start] key.
* :Output the automatic adjustment chart.
Method: Execute
1.Place an original on the table and press the [Start] key.
* :Execute the automatic adjustment.
2.When adjustment has normally completed, [OK] is displayed.
* :An error code appears when there is an error.
Error codes list
U469
Color registration adjustment
(Message: Adj Cor Reg)
Items
Contents
Auto
Adjust the color registration automatically
Manual
Adjust the color registration manually
Items
Contents
Output the automatic adjustment chart.
Execute
Start scanning and execute the automatic adjustment.
Error codes
Place of occurrence
Factor
S001
Scanner
Original reference patch is not detected
S002
Scanned image position shifted in excess in the
main scanning direction.
S003
Scanned image position shifted in excess in the
sub scanning direction.
S004
Original skew is in excess
S005
Original type mismatch
SFFF
Other scanning error
E001
Engine
Engine error
CFFF
Controller
Other errors