2R4/2R5/2R6
6-44
Contents
Adjusting the magnification for DP scanning.
Purpose
Adjusted if the magnification is incorrect in the auxiliary scanning direction when the DP is used
Adjustment
1.Press the [Start] key.
2.Press the [System Menu/Counter] key.
3.Place an original on the DP and press the [Start] key to make a test copy.
* :Check the duplex scanning by setting [Duplex] when test copying.
4.Press the [System Menu/Counter] key.
5.Select the item to adjust.
6.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
For the copy example 1, increase the value.
For the copy example 2, decrease the value.
* :When the setting value is increased, the image get longer, and it shortens when the setting
value is decreased.
Figure 6-11
7.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U070
DP magnification adjustment
(Message: Adj DP Motor)
Items
Contents
Setting
range
Initial
setting
Data
varia-
tion
SubScan(F)
Adjusting the magnification for table scanning
-25 to 25
-
0.1 %
SubScan(B)
Adjusts the 2nd side magnification in the sub
scanning direction when duplex scanning
-25 to 25
-
0.1 %
Duplex 1side
Adjusts the 1st side magnification in the sub
scanning direction when duplex scanning
-25 to 25
-3
0.1 %
Original
Copy
example 1
Copy
example 2