2R4/2R5/2R6
6-347
Contents
Enter the lab values which are shown on the back page of the adjustment original (P/N:
7505000107).
Purpose
Enter data in order to correct for differences in originals during the automatic adjustment
Method
1.Press the [Start] key.
2.Select the item to set.
Method: ChartA
1.Press the [Start] key.
2.Select the item to set.
Setting: White
1.Select the item to set.
2.By using [Left/Right cursor] keys or the numeric keys, enter the values which are shown on the
back page of the adjustment original.
3.Press the [Start] key to set the setting value.
U425
Set Target
(Message: Set Target)
Items
Contents
ChartA
Setting the adjustment value of the table scanning
ChartB
Sets the adjustment value of the DP scanning
Items
Contents
White
Setting the white patch for the adjustment original
Black
Setting the black patch for the adjustment original
Gray1
Setting the Gray1 patch for the adjustment original
Gray2
Setting the Gray2 patch for the adjustment original
Gray3
Setting the Gray3 patch for the adjustment original
C
Setting the cyan patch for the adjustment original
M
Setting the magenta patch for the adjustment original
Y
Setting the yellow patch for the adjustment original
R
Setting the red patch for the adjustment original
G
Setting the green patch for the adjustment original
B
Setting the blue patch for the adjustment original
Adjust Original
Setting the main scanning and sub-scanning directions
Items
Contents
Setting range
Initial
setting
Data
variation
L
L parameter setting
0.0 to 100.0
93.6
-
a
A value setting
-200.0 to 200.0
0.9
-
b
B value setting
-200.0 to 200.0
-0.4
-