Displays the machine serial number and drum counter history.
Purpose
Execute to check the machine serial number and drum counter values.
Method
1.Press the [Start] key.
* :Select the item to refer to.
* :Displays the machine serial number and 3 items of the drum counter history.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Set the drum sensitivity.
Purpose
Execute when the drum unit or laser scanner unit is replaced.
After completing, execute maintenance mode U464 [Calibration].
Method
1.Press the [Start] key.
2.Select [Execute].
3.Press the [Start] key.
* :Starts the drum setup operation.
4.Turn the power switch off then on. Wait more than 5 seconds between the power off and on.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U118
Drum unit history
(Message: Drum Unit History)
Items
Contents
C
Displays the cyan drum history
M
Displays the magenta drum history
Y
Displays the yellow drum history
K
Displays the black drum history
Items
Contents
Machine History1 to 3
Machine serial number history
Cnt History1 to 3
The drum counter history
U119
Setting the drum
(Message: Set Up Drum Unit)
Items
Contents
Execute
Detect the main charge current and save the current value.