2R4/2R5/2R6
6-113
Contents
Adjusts the margins for DP scanning.
Purpose
Make the adjustment if margins are incorrect
Adjustment
1.Press the [Start] key.
2.Press the [System Menu/Counter] key.
3.Place an original on the DP and press the [Start] key to make a test copy.
4.Press the [System Menu/Counter] key.
5.Select the item to adjust.
6.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
* :When the setting value is increased, the margin widens, and it narrows when the setting
value is decreased.
Figure 6-17
7.Press the [Start] key to set the setting value.
Precautions
Check the copy image after the adjustment. If the image is still incorrect, adjust the following in
the maintenance mode.
U034 (P.6-228) > U402 (P.6-332) > U403 (P.6-333) > U404
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U404
Adjusting margins for scanning an original from the docu-
ment processor
(Message: Scan Margin DP)
Items
Contents
Setting
range
Initial
setting
Data
varia-
tion
A Margin
Adjusts the DP left margin
0.0 to 10.0
3.0
0.5mm
B Margin
Adjusts the DP leading edge margin
0.0 to 10.0
2.5
0.5mm
C Margin
Sets the DP right margin
0.0 to 10.0
3.0
0.5mm
D Margin
Adjusts the DP trailing edge margin
0.0 to 10.0
4.0
0.5mm
Left margin
(Within 4.0mm)
Right margin
(Within 4.0mm)
Trailing edge margin
(Within 4.0mm)
Leading edge margin
(
4.0 +1.5/-0