2R4/2R5/2R6
6-320
Contents
Switch the operations and screens of the main unit according to the destination.
Purpose
Execute after initializing the backup RAM, in order to return the setting to the value before
replacement or initialization
Method
1.Press the [Start] key.
2.Select the item to set.
*1
: 100 V model only,
*2
: Except 100 V model
* :Initial setting: Destination
3.Press the [Start] key.
* :Initializes according to the destination
4.Turn the power switch off then on. Wait more than 5 seconds between the power off and on.
* :An error code is displayed when an error occurs.
When errors occur, turn the power switch off then on, and execute initialization using mainte-
nance mode U252.
Error codes
U252
Destination
(Message: Set Destination)
Items
Contents
Japan Metric
*1
Japan metric
Inch
*2
Inch
Europe Metric
*2
Europe Metric
Asia Pacific
*2
Asia Pacific
Australia
*2
Australia
China
*2
China
Korea
*2
Korea
Items
Contents
0001
Controller (Entity Error)
0002
Controller error
0020
Engine error
0040
Scanner error
Summary of Contents for TASKalfa 306ci
Page 36: ...2R4 2R5 2R6 2 6 35 ...
Page 191: ...2R4 2R5 2R6 2 6 190 ...
Page 233: ...2R4 2R5 2R6 6 232 ...
Page 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Page 280: ...2R4 2R5 2R6 6 279 ...