About the Edge SS Manual Servo Control Tab
2-43
KVAL Operation/Service Manual
About the Edge SS Manual Servo Control Tab
Select the
Manual Servo Control Tab
to jump to the screen. At this screen, the
Main Head
and
Table
servo motors can be moved manually. Table controls include moving the
Feeler
and the
Feeder
.
Table Feed
Control is an
Optional Fea-
ture
FIGURE 2-5.
Edge-SS Manual Control Screen
About the Edge-SS Feeler Servo Controls
These controls operate the
Thickness Feeler
. The feeler uses encoder technology to accu-
rately measure the thickness of a door. For information about the Feeler, see
“About the
Door Length Feeler” on page 6-8
LengthFeelerEncoder:
Dis-
plays the Count Position of the
Feeler Encoder.
Feeler Forward:
Press
and Hold to move the
feeler forward. (Toward
from the door)
Feed Reverse:
Press and
Hold to move the feeler in
reverse. (Away from the
door)
Feeler Retracted:
Press
to toggle feeler contacts to
and away from the door.
Summary of Contents for Edge-SS
Page 5: ...KVAL Edge SS Operation Service Manual ...
Page 12: ...KVAL Edge SS Line Operation Service Manual ...
Page 32: ...Safety Sign Off Sheet 1 20 KVAL Operation Service Manual ...
Page 35: ...Definitions 2 45 KVAL Operation Service Manual ...
Page 91: ...Definitions KVAL Operation Service Manual 2 56 ...
Page 109: ...System IT Administration 4 4 KVAL Operation Service Manual ...
Page 142: ...Collet Torque Values 5 33 KVAL Operation Service Manual ...
Page 143: ...Troubleshooting Electrical Problems 6 30 KVAL Operation Service Manual ...
Page 173: ......
Page 177: ......
Page 178: ......
Page 179: ......