About the Calibration Tabs
3-4
KVAL Operation/Service Manual
Unlock the Calibration (Option)
Access to the calibration is password protected. (Optional)
1.
Select the
Unlock
button
2.
At the
Password
pop-up, enter
the password and select OK to
continue.
3.
The calibration message will
change from a red ''Calibration is
Locked '' to a green Calibration is
Unlocked”.
Enter a Positive or Negative Number?
Determine when to enter a positive of negative number by using your
Left Hand
. Use the cut on
the door as a reference. Hold out the left hand with the first finger pointed at the
door cut
, second
finger and thumb at right angle to each other. The first finger represents the
positive
direction of
the ‘Z” axis, the thumb represents the
positive
direction of the ‘Y” axis, then second finger rep-
resents the
positive
the direction of the ‘X’ axis.