Valve Bank Locations
6-18
KVAL Operation/Service Manual
Valve Bank Locations
The
Figure
6-29
shows the locations of the valve banks on the machine. The valve banks include
control valves (solenoids) that drive cylinders to move different loads in the machine. The sole-
noid if controlled by the PLC by applying a high voltage or a low voltage to a control coil. Con-
trols for example are: extending and retracting router, drill, clamping a door.
Valve banks are normally located near the load that they drive.
Note:
Labels on the solenoids identify loads they control.
Location of Valve Banks on the Edge-SS
Table Valve Bank 2
Table Valve Bank 1
Cutter Head Valve Bank
Deep Drill Valve Bank
FIGURE 6-29.
Location of Valve Banks
The table below lists the typical loads controlled by the valve banks.
Note:
The values in this table are typical. To verify, check the labels on the solenoids
and the air schematic.
TABLE 6-2.
Valve Bank
Loads (Cylinders)
Extend and Retract: Stops, Feeler, Dust Hoods, Lower Door
Extend and Retract:; Clamps, Lift Table
Extend and Retract: Chisels (X4),Hinge Router, Router, CR Router, Deep Mortise
Extend, Retract., and Lift, Air Inject for Deep Drill
Table Valve Bank 1
Table Valve Bank 2
Cutter Head Valve Bank
Deep Drill Bank
Summary of Contents for Edge-SS
Page 5: ...KVAL Edge SS Operation Service Manual ...
Page 12: ...KVAL Edge SS Line Operation Service Manual ...
Page 32: ...Safety Sign Off Sheet 1 20 KVAL Operation Service Manual ...
Page 35: ...Definitions 2 45 KVAL Operation Service Manual ...
Page 91: ...Definitions KVAL Operation Service Manual 2 56 ...
Page 109: ...System IT Administration 4 4 KVAL Operation Service Manual ...
Page 142: ...Collet Torque Values 5 33 KVAL Operation Service Manual ...
Page 143: ...Troubleshooting Electrical Problems 6 30 KVAL Operation Service Manual ...
Page 173: ......
Page 177: ......
Page 178: ......
Page 179: ......