12,000 Cycle Maintenance Steps
5-10
KVAL Operation/Service Manual
12,000 Cycle Maintenance Steps
Follow Lockout Tagout procedures.
Inspect Chains for Proper Tension
Inspect chains for proper tension or damage.
Check for sagging chains. Chains can stretch
over time of use.
Check for chain stiffness. Stiff chains do not
provide a tight fit over the gears.
Inspect Air Cylinders
Inspect all air cylinders for air leaks. Replace the cylinder if seal is leaking. Symptoms include a
cylinder not extracting or retracting to the limits. Cylinders not holding their position.
Inspect Hydraulic Lines
Inspect hydraulic lines for loose fittings,
leaks and cracks.
Inspect hydraulic lines from the source to
the end assembly.